13
TsDHW
is reached, will start collector pump
P2
in order to lower temperature below critical.
Wait for collector cool down. If menu option
“
Alarm TCOLcr
” is set as
NO
, controller will not
report this alarm, but it will take described
actions.
12
Solar panel A overheating. P1 stop
A
circuit collector pump (at scheme
H
) will be
stopped, until collector temperature drops below
TCOLmax
. It is possible to start pump in
manual service mode.
13
Solar panel B overheating. P2 stop
B
circuit collector pump (at scheme
H
) will be
stopped, until collector temperature drops below
TCOLmax
. It is possible to start pump in
manual service mode.
14
Antifreeze STOP
During antifreeze performance collector pump is
started to increase temperature of too cold solar
work fluid. Energy from reservoir or pool will be
used for this purpose. However, if reservoir or
pool temperature is near 2°C, controller w
ill stop
antifreeze function to prevent heat source
damage and will initiate alarm. Antifreeze
function
is
wider
described
in
section
10.
OPTIONS MENU
Access
You must log-in to enter the options. Login
screen is presented in Fig. 10.1
Fig. 10.1 User login screen
Access to this menu is protected with
password. This menu settings are used by
installer/servicer. Detailed description of the
options parameters is included in installation part
of the manual.
Password
0000
will
display
submenu
parameters only for reading.
10.1.
Restoring factory settings
This
menu
allows
restoring
factory
parameters and settings. In login screen enter
password
0002
and confirm to restore only
default user settings. Service parameters will not
be changed. After restoration of factory settings,
parameters available in
Options
menu will not be
changed.
Before restoration the controller will show a
request to confirm this action.
After restoring factory settings you must set
the clock, as it has been reset to date: 00:00,
01-01-2010.
10.2.
Reading default settings
The controller has default settings table (that
will be restored). Default settings may be read by
entering password
0005
in login screen. The
table is only for reading type and it may not be
edited.
10.3.
Clearing heat output data
Password
0003
will clear any heat output
chart in the controller.
Password
0004
will clear heat output
counter.
After entering passwords
0003
and
0004
the
controller
will
display
request
for
confirmation. Select “NO” to exit without
changes.
List of codes
0000
Table of option submenu settings only
for reading
0002
Restores default settings of
User
group
(not protected with password)
0003
Clears heat output chart
0004
Clears heat output counter
0005
Default settings table
Access to
Options
submenu
Restores default settings in groups
User and Service
in controller (all
parameters)
11.
OPERATION MANU
This menu is dedicated to the user. Here, you
may change basic settings of the controller only
operation.
11.1.
Operation\Settings Menu
Access
This menu allows the user to access:
Nameplate
–
It has three pages. Navigate
between pages by turning the knob left/right.
First page (1/3)
allows you to read
information on the unit hardware and
software version;
Summary of Contents for PCSol 201
Page 2: ......
Page 6: ......
Page 7: ...OPERATING MANUAL PCSol 201 ...
Page 27: ...INSTALLATION MANUAL PCSol 201 ...
Page 54: ...54 ...
Page 55: ......
Page 56: ...SALUS Controls Made in Poland ...