6. Output terminals for actuators

INSTALLATION

Wires of the thermoelectric actuators should be plugged into the self-locking connectors in the 

appropriate zones. You can connect 3 actuators directly to one zone. The current load of one zone is 

adapted to operate with up to 6 thermoelectric actuators with a power of 2 Watts. If there is a need to 

connect more than 6 actuators please use an additional relay to relieve the output of the zone.

Note: 

On the actuator contacts, 

there is voltage 230 V AC during 

their work.

Remove the top cover of the KL04RF.

Connect the thermoelectric actuators wires.

Connect KL08RF and KL04RF using serial connector.

Make sure that all the wires are properly connected, mount top cover and power up the wiring 

centre - “Power” and “Connection” 

red

 LED diodes will light up indicating the correct connection 

with the KL08RF wiring centre.

Mount the back side of the housing to the wall.

When mounting on a DIN rail, open the hooks on the back of the housing.

Thread the power supply wires through and connect them to the “L” and “N”  terminals.

Remove the appropriate piece  

of insulation from the wires.

1

2

4

6

5

7

3

KL04RF power supply

(min. 2x1,0 mm

2

 230 V

max. 2x1,5mm

2

 230 V)

The operation was explained on the example  

of T30NC actuators.

4. Power supply diode

5. Work status indication of each zone

3. Connection diode

Green led diode lights up when the heating demand signal is being transmitted from the thermostat  

to the given zone (with NC actuators connected).

If KL04RF module is properly connected to the KL08RF wiring centre, connection diode will 

light solid 

red

.

After connecting the KL04RF module to the power supply, Power led diode will light solid 

red

.