Introduction

1. Serial connector

2. Power supply

Wiring Centre Description

Product Compliance

Technical Information

The KL04RF module is an extension to the KL08RF wiring centre for an additional 4 heating zones. Works 

only in combination with KL08RF wiring centre and increases its functionality up to 12 individual heating 

zones.

It is used for communication between KL08RF wiring centre and KL04RF extension module. Combined 

set increases support up to 12 zones.

KL04RF

This product complies with the essential requirements and other relevant provisions of the following 

EU Directives: EMC 2014/30/EU, Low Voltage Directive LVD 2014/35/EU, Radio directive 2014/53/EU  

and RoHS directive 2011/65/EU. The full text of the EU Declaration of Conformity is available at the 

following internet address: www.saluslegal.com

Use in accordance with national and EU regulations. Device is intended for indoor use only in dry 

conditions. Product for indoor use only. Installation must be carried out by a qualified person in 

accordance to national and EU regulations.

Before attempting to setup and install, make sure that KL04RF is not connected to any power source. 

Installation must be carried out by a qualified person. Incorrect installation may cause damage to the 

wiring centre. The KL04RF should not be installed in areas where it may be exposed to water or damp 

conditions.

Safety Informations

Manual

Wiring centre extension for KL08RF

Model: KL04RF

1.  

Serial Connector 

 

2.  

Power Supply

 

3.  

Connection diode 

4.  

Power supply diode

5.  

Work status indication of each zone

6.  

Output terminals for actuators

230 V AC

L

N

Power supply for wiring centre is 230V ~, 50Hz.

Features of the installation:

• two-wire, with PE protective conductor,

• made in accordance with applicable regulations.

Power Supply

230 V AC

Max load

3 A

Outputs

Thermoelectric actuator 230V AC

Dimensions [mm]

163 x 85 x 67