 (schedule for  the working 

days and for the weekend)

Press MENU. Using UP or DOWN adjust 

the  HOLIDAY and then press OK.

Using UP or DOWN, set the 

day and then press OK.

Press MENU.

Now do the same steps

to set holiday mode’s final day.

Press OK.

Using UP or DOWN, set the

hour and then press SELECT.

Using UP or DOWN, select the warning 

period and then press OK.

Using UP or DOWN, enter the phone 

number. Press OK to confirm every digit.

Once service mode has become active, the device will lock the set point temperature as set by the installer/landlord. 

To unlock this device, the landlord needs to be contacted and the boiler serviced.

Thermostat will maintain the temperature until manual change or manual mode exit. To turn off the Manual Mode 
press HAND button. Once the manual mode is off, the HAND icon on the thermostat will disappear.

Press the UP arrow on the interval 

at which you want to remove the 

temperature, until lines appear

This function is available in Automatic and Manual Mode . It is used to change the setpoint temperature for a specified number 
of hours ( up to 9 hours ) . Once that time is over , thermostat returns to previous mode.

Landlord settings is a pin code protected feature that allows the landlord to set a service reminder on the thermostat that will 
warn the tenant when the boiler is due its annual service.

In this mode thermostat does not Work according to the programmed schedule but it will maintain selected temperature.

Using UP or DOWN, 

set new setpoint temperature

After new setpoint temperature set,

thermostat will return to the main screen.

All 

(set one schedule for

the entire week)

Using UP or DOWN, set the 

year and then press OK.

Using UP or DOWN, set the 

hour and then press OK.

Using UP or DOWN, navigate to 

Landlord submenu and press OK.

Using UP or DOWN, set the

minutes and then press OK.

Using UP or DOWN, select the 

due date and then press OK.

When lines appear, press OK to confirm 

the removal of that specific interval

Please see below an example for 

your weekly schedule. 

High temperature should be 

used for the ON times and  low 

temperature for the OFF times.

Individual 

(set a daily schedule).

Press OK to confirm.

Using UP or DOWN, set the 

month and then press OK.

Using UP or DOWN, set the 

minutes  and then press OK.

Using UP or DOWN, enter the PIN code 

number. Press OK to confirm every digit.

Using UP or DOWN, set the temperature 

which should be maintaned during 

holiday mode and then press OK.

Using UP or DOWN, select 

ON and press OK.

According to set period of time the Holiday 

icon will appear on the main screen and 

thermostat is working in holiday mode.

Using UP or DOWN, select the 

due date and then press OK.

Using UP or DOWN, set the

temperature and then press OK.

Press OK.

Now you can check your settings. 

If you want to make a change, 

press UP or DOWN on the 

relevant screen.

If you do not want to use the 6 temperature intervals / day (ex: 1 eco, 2 comfort), please see below how to delete one 

or more intervals.

This function is available only in automatic mode ( Schedule ). If a new setpoint temperature will be set during the 

schedule - it will be maintained until next time interval starts according to programmed schedule.

In this mode the “frost protection” temperature is maintained for a specific number of days.

Repeat the process for all time periods.

Temporary Override mode will be disabled when new schedule will be set.

The first time when you want to use Landlord Mode, you will have to set the pin code. Once the PIN code has 

been set, you can use the Landlord settings.

TIME:

06.00

10.00

12.00

14.00

18.00

21.00

6 temp / day

- eco -

21 °C

14 °C

21 °C

14 °C

21 °C

14 °C

2 temp / day

- comfort -

21 °C

-

-

-

-

14 °C

Temporary Override Mode

Setting the CONTROL

Landlord Settings

Hourly temperature Override Mode (+Hr)

Thermostat Pairing with the Receiver

Thermostat Pairing with the Receiver

Factory Reset

Manual Mode and setting setpoint temperature

Holiday Mode

OK

OK

OK

OK

OK

OK

Press + Hr button to set number of hours 

for temperature override

 (e.g. to set up override for 3 hours , press the button 3 times)

Press OK to confirm.

Press HAND button to activate 

the Manual Mode.

Using UP or DOWN, set  a new 

setpoint temperature of override

After new setpoint temperature set,

thermostat will return to the main screen.

1

1

2

3

2

4

OK

OK

Using UP or DOWN, set 

new setpoint temperature

Press OK to confirm.

After new setpoint temperature set, 

thermostat will return to the main 

screen.

3

4

5

Note:

 If you are using the DT600RF pack, the pairing between the thermostat and the receiver is already done. 

During the pairing process, please make sure the thermostat and the receiver are at least 1 meter from each other.

If you want to re-pair the devices with each other, follow the steps below:

Important note:

 The communication radius of the thermostat with the receiver is of maximum 100m, in 

open space. In built space, with various obstacles (eg walls, floors, metal structures, furniture elements), the 
communication radius will be significantly reduced. RF communication can be disrupted by local factors, such 
as GSM antennas, radio frequency devices or toys, or other equipment that produces electromagnetic interfer-
ence. Receivers for the boiler must be powered from a stable voltage source, without frequent interruptions or 
voltage fluctuations (outside the standard tolerance). The manufacturer is not responsible for identifying or 
combating the effects of local disturbances.

ON

OFF

MANUAL AUTO

ON

OFF

MANUAL AUTO

ON

OFF

MANUAL AUTO

Move the left switch to the OFF 

position with a quick motion and 

back to the ON position

The green LED will start blinking, 

which will confirm that the receiver 

has entered the pairing mode.

Make sure that the receiver is 

disconnected from the power supply 

 

and the switches on it are in the AUTO 

and ON positions. Then connect the 

receiver to the power supply and wait for 

the green LED to glow continuously.

1

2

3

OK

OK

OK

OK

OK

OK

OK

OK

4

1

1

2

7

5

2

6

3

Press MENU.

Press MENU. Using UP or DOWN, 

select TEST and press OK.

To reset the thermostat, press 

+Hr, DOWN and UP buttons 

simultaneously for 5 seconds.

The device will be reset and 

will start up automatically.

The pairing process takes up to 10 minutes.

Once devices are successfully paired,

LED on the receiver will go solid green.

Using UP or DOWN, navigate to 
Pairing submenu and press OK.

The testing process takes

up to 10 minutes.

Using UP or DOWN, select 

PAIR and press OK.

The green LED and the yellow LED 
on the receiver will begin to flash.

ON

OFF

MANUAL AUTO

Landlord settings will not be reset.

To turn off Boost mode, press and hold the + Hr button until the override time disappears, or press the + Hr 

button repeatedly until “+0” appears.

OK

OK

OK

OK

OK

OK

4

5

4a

6

Optimum Start is a selectable function which, depending on the ambient room temperature, will start the boiler operation at 

the optimum time to achieve the set-point temperature. It saves energy by only firing the boiler for the minimum required time.

Optimum Stop calculates how long the house will take to cool down, then turns off the boiler at the earliest possible moment, 

this means the system is not running when it’s not actually necessary. If there is a sudden heat loss during this period, then 

Optimum Stop will be overridden to regain comfort conditions.

Press OK.

Press OK to confirm.

Using UP or DOWN, select ON or OFF

Using UP or DOWN, select Optimum START or Optimum STOP. 

Press OK to confirm.

Optimize function

4a

4b

OK

OK

OK

OK

OK

OK

OK

OK

3

2a

3a

2b

1

3b

2c

2

Press OK.

Span is the temperature difference, between which thermostat operates and keeps setpoint temperature. For example, if 
you set setpoint temperature to 20°C and if the hysteresis is ± 0.5°C, heating will be turned on when the room temperature 
drops to 19.5°C and turned off when the room temperature reaches 20.5°C.

TPI (Time Proportional & Integral) is a self-learning, time proportional algorithm. 
TPI type of regulation ensures economical system operation through more 
accurate temperature maintenance during controlling process and limits overload 
conditions. In addition to the exact and stable room temperature, the advantage 
of this system is the minimization of energy consumption and significant savings. 
The product offers 3 types of TPI control: 1. for radiator (6CPH); 2. for underfloor 
heating (3CPH); 3. for electric heating (9CPH).

From the two algorithms below, you can select only one of the 

algorithms, TPI or SPAN.

Using UP or DOWN, 

select the Span value.

Using UP or DOWN, select the TPI type  you want to use. Press OK to confirm.

Press OK to confirm.

Press OK.

Press MENU. Using UP or DOWN 

adjust the CONTROL and then press OK.

Summary of Contents for DT600

Page 1: ...me Group Maintaining a policy of continuous product development SALUS Controls plc reserve the right to change specification design and materials of products listed in this brochure without prior notice SALUS Controls Units 8 10 Northfield Business Park ForgeWay Parkgate Rotherham S60 1SD Email sales salus tech com ...

Page 2: ...ormation UseinaccordancetonationalandEUregulations Usethedeviceasintended keepingitindrycondition Productforindoor use only Installation must be carried out by a qualified person in accordance to national and EU requlations Technical specification DT600Thermostat DT600RFThermostat Thermostat supply 2xAAalkalinebatteries 2xAAalkalinebatteries Thermostat rating max 5 3 A OpenTherm terminals A B Outp...

Page 3: ...or Manual Mode On Program number Invalid icon Temperature measured set Landlord Mode On Boost function Holiday Mode On Frost Protection Mode On Temperature unit Clock Low battery status Heating Mode On Wireless connection with the receiver Only for RF thermostat AM PM Text bar 1 18 17 16 15 14 13 2 3 4 5 6 9 7 10 8 11 12 DT600ThermostatTerminals Description DTRX6 ReceiverTerminals Description Term...

Page 4: ...rmostat OR DT600ThermostatWiring Diagram OR Power Up and Configuration Please make the receiver connections and power the receiver before inserting the batteries into the thermostat 1 10 4 7 11 5 8 3 12 6 9 After inserting the batteries the thermostat will power up Press OK to confirm Using UP or DOWN set the hour and then press OK Using UP or DOWN set the month and then press OK Using UP or DOWN ...

Page 5: ... is in operation Using UP or DOWN navigate to CH MAX submenu and press OK Using UP or DOWN adjust the PROGRAM and then press OK Using UP or DOWN select the program type between 5 Using UP or DOWN set MAX temperature for boiler and then press OK to confirm Using UP or DOWN select your temperature accuracy Using UP or DOWN adjust the temperature and then press OK The thermostat will return to the ma...

Page 6: ...e ON times and low temperature for the OFF times Individual set a daily schedule Press OK to confirm Using UP or DOWN set the month and then press OK Using UP or DOWN set the minutes and then press OK UsingUPorDOWN setthetemperature whichshouldbemaintanedduring holidaymodeandthenpressOK AccordingtosetperiodoftimetheHoliday iconwillappearonthemainscreenand thermostatisworkinginholidaymode Using UP ...

Page 7: ...ing UP or DOWN select ON or OFF Using UP or DOWN select Optimum START or Optimum STOP Press OK to confirm Optimize function 4a 4b OK OK OK OK OK OK OK OK 3 2a 3a 2b 1 3b 2c 2 Press OK Span is the temperature difference between which thermostat operates and keeps setpoint temperature For example if yousetsetpointtemperatureto20 Candifthehysteresisis 0 5 C heatingwillbeturnedonwhentheroomtemperature...

Page 8: ...illmaintainselectedtemperature Using UP or DOWN select the due date and then press OK UsingUPorDOWN select ONandpressOK UsingUPorDOWN selectthe duedateandthenpressOK Press OK Now you can check your settings If you want to make a change press UP or DOWN on the relevant screen Hourly temperature Override Mode Hr Manual Mode and setting setpoint temperature OK OK OK OK OK OK Press Hr button to set nu...

Page 9: ... for the boiler must be powered from a stable voltage source without frequent interruptions or voltage fluctuations outside the standard tolerance The manufacturer is not responsible for identifying or combating the effects of local disturbances ON OFF MANUAL AUTO ON OFF MANUAL AUTO ON OFF MANUAL AUTO Move the left switch to the OFF position with a quick motion and back to the ON position The gree...

Reviews: