MAINTENANCE

The CT100 thermostat requires no special
maintenance. Periodically, the outer casing can be
wiped clean using a dry cloth (please DO NOT use
solvents, polishes, detergents or abrasive cleaners,
as these can damage the thermostat).

There are no user serviceable parts within the unit;
any servicing or repairs should only be carried out
by Salus Controls or their appointed agents.

Should the CT100 thermostat fail to function 
correctly, check:

The CT100 temperature has been set correctly.

Heating system time switch or programmer 
is switched on.

CT100 INSTRUCTION MANUAL

7

WARRANTY

Salus Controls warrants that this product will be
free from any defect in materials or workmanship,
and shall perform in accordance with its
specification, for a period of two years from the
date of installation. Salus Controls sole liability for
breach of this warranty will be (at its option) to
repair or replace the defective product. 

CT100 INSTRUCTION MANUAL

8

PRODUCT SPECIFICATION

Model:

CT100

Type:

Surface mounted mechanical
thermostat designed for hot water
cylinder or pipe applications.

Dimensions

Height:

105 mm

Width:

45 mm

Depth:

50 mm

Switching

Switching Voltage: 230V AC, 50Hz
Switching Current: 16A resistive, 4A inductive
Contact Type:

Single Pole Double Throw (SPDT) 

Temperature

Range:

40 ºC to 80 ºC

Environment

Operating Temperature: 0 ºC to + 55 ºC
Storage Temperature:

- 20 ºC to + 60 ºC