2-4
Module 2 – Wireless Accessories
SS881ZB Embedded Door Sensor
Section 2
Step 1.
Apply a self-
adhesive drill guide
to mark the desired
location .
Step 2.
Drill a 7/8”
diameter hole at least 2 .6”
deep through the guide .
Then remove the guide
remnants .
Step 3.
Insert the sensor
sleeve in the hole until the
flange seats on the surface .
SALUS recommends locating the embedded door sensor in the door jamb on the hinge
side of the door so that closing the door activates the plunger (A1 Above) . If this location
is not convenient due to obstacles such as glass panels, the sensor can be mounted
on the opposite door jamb (A2), in the lintel above the door (B) or in the door itself (C) .
Location C is not recommended for steel doors due to potential signal interference issues .
If required, remove the flange from
the sleeve before inserting.
Installation Instructions