1.1.4 Right panel

 

Table 1-4 

Right 

panel description

No.

Function

Description

A

Serial communication interface

Used for serial communication

B

Trigger interface

External trigger input interface

1.2 Preparation before use

1.2.1 General inspection

When you get a new monitoring receiver, please follow the steps below to check it.

1)

Check whether there is any damage caused by transportation and whether the 

accessories are complete

Please keep the damaged shipping packaging or shock-proof materials until the goods have

 

been completely inspected and the module has passed the electrical performance and

 

mechanical tests. Standard accessories can be checked according to the "packing list" in the 
box

 

to see if they are missing.

2)

Check the whole machine

If there is any mechanical damage or missing, or the module fails the electrical performance 
and

 

mechanical tests, please contact our company.

3) Connect power

The monitoring receiver module is powered by an AC/DC adapter power supply or a 
regulated

 

DC power supply.

1.2.2 Connect adapter power

Please use the power cord and adapter provided in the accessory to connect to the monitoring 

receiver module.

S

MR

 Series 

Monitoring Receiver Module

 

Quick Start

 Manual

Figure 1-4 Right panel view

9

 

/

 

1

1

Summary of Contents for SMR Series

Page 1: ...SMR Series Monitoring Receiver Module Quick Start Manual Saluki Technology Inc...

Page 2: ...irements 5 Confirm power supply 6 Prevent mutual interference via power supply 6 Confirm power cord 6 1 Quick start 7 1 1 Appearance interface description 7 1 1 1 Front panel 7 1 1 2 Left panel 8 1 1...

Page 3: ...herwise the user will be responsible for all consequences arising therefrom Use the correct power supply Different countries or regions have different power supply standards Please check whether the p...

Page 4: ...instrument or the risk of electric shock do not operate the instrument in a humid environment Do not operate in flammable and explosive environments To avoid instrument damage or personal injury do no...

Page 5: ...supply and turn off the instrument Use a damp but non drip soft cloth you can use mild detergent or clean water to wipe the dust on the outside of the instrument Neutral computer cleaning paste can al...

Page 6: ...wing terms may appear on the product 1DANGER means that there may be immediate danger to you if you perform this operation 2WARNING Indicates potential hazards to you if you perform this operation 3CA...

Page 7: ...onment the heat dissipation space requirements of the instrument should be met The heat dissipation distance at the rear of the instrument is 150mm The heat dissipation distance between the left and r...

Page 8: ...ly to power the instrument Confirm power cord The instrument uses a three core power cord interface which complies with national standards You must confirm that the power protective ground wire is rel...

Page 9: ...tion 1 1 1 Front panel Figure 1 1 Front panel view Table 1 1 Front panel description No Function Description A Power interface 12V power supply connector If necessary the adapter interface can be B US...

Page 10: ...ce clock output RF 10M clock output interface C 10M reference clock input RF 10M clock input interface D 145M clock output IF 145M clock output interface 1 1 3 Back panel Figure 1 3 Back panel view Ta...

Page 11: ...een completely inspected and the module has passed the electrical performance and mechanical tests Standard accessories can be checked according to the packing list in the box to see if they are missi...

Page 12: ...power supply interface of the module and power it on After the startup is completed the system status indicator light changes from red to green At this time the PC host computer can be connected norm...

Page 13: ...uct warranty period is one year For detailed warranty instructions please refer to the Saluki Electronic Product Warranty Card Except for the guarantees provided in this summary or other applicable wa...

Reviews: