Dismantling the GFA Module
The instruction below shows an example of a GFA module. The module comprises a housing which
contains a number of gears depending on model of the GFA system.
To dismantle the GFA module:
1.
Loosen the shaft lid.
2.
Remove the shaft lid.
3.
Loosen and remove the screws. The number and type of screws depend on the GFA model.
4.
Place the GFA module on a rubber mat. Hit the shafts to loosen the upper and lower part of the
housing.
5.
Open the housing.
6.
Remove the bearing housing and the snap ring, shim ring and needle carrier if needed.
7.
Remove the output gear, middle gears and input gears. The amount of gears depend on the GFA
model.
Note the direction of the output gear (hexagonal shape up or down). It should be placed in the
same way when assembling the GFA module.
8.
Remove the needle rollers.
Depending on the GFA model the needle rollers can be loose or assembled in bearing rings.