BPW-9101-GB

AUTOMATIC WRIST BLOOD PRESSURE MONITOR

Instructions and Guarantee

E

Summary of Contents for BPW-9101-GB

Page 1: ...BPW 9101 GB AUTOMATIC WRIST BLOOD PRESSURE MONITOR Instructions and Guarantee E ...

Page 2: ...ntended for use in measuring blood pressure and heartbeat rate with wrist circumference ranging from 13 5cm to 21 5 cm about 5 8 It is intended for adult indoor use only Contraindications 1 The device is not suitable for use on pregnant women or women who think they may be pregnant 2 The device is not suitable for use on patients with implanted electrical devices such as cardiac pacemakers defibri...

Page 3: ... pressure Never change a prescribed medication without consulting your physician Do not take any therapeutic measures on the basis of a self measurement Never alter the dose of a medicine prescribed by a doctor Consult your doctor if you have any question about your blood pressure When the device was used to measure patients who have common arrhythmias such as atrial or ventricular premature beats...

Page 4: ... emergencies or operations Otherwise the patient s wrist and fingers will become anaesthetic swollen and even purple due to a lack of blood When not in use store the device in a dry room and protect it against extreme moisture heat lint dust and direct sunlight Never place any heavy objects on the storage case This device may be used only for the purpose described in this booklet The manufacturer ...

Page 5: ...with this device such as setting up maintaining or using please contact the SERVICE PERSONNEL of Salter Don t open or repair the device by yourself in the event of malfunctions The device must only be serviced repaired and opened by individuals at authorized sales service centers Please report to Salter if any unexpected operation or events occur Keep the unit out of reach of infants young childre...

Page 6: ...6 LCD DISPLAY SIGNAL ...

Page 7: ...7 MONITOR COMPONENTS 1 Automatic Wrist Blood Pressure Monitor 2 2 x AAA batteries 3 User manual list of ...

Page 8: ...rent types of batteries together Do not dispose the batteries in fire Batteries may explode or leak Remove batteries if the device is not likely to be used for some time Worn batteries are harmful to the environment Do not dispose with daily garbage Remove the old batteries from the device following your local recycling guidelines CAUTION Replace the batteries under following circumstances display...

Page 9: ...r so that a time stamp can be assigned to each record that is stored in the memory The setting range of the year 2018 2058 time format 24H 1 When the monitor is off hold pressing MEM button for about 3 seconds to enter into setting mode The blinking numeral represents YEAR 2 Press the MEM button to change the YEAR Each press will increase the numeral by one in a cycling manner 3 When you get the r...

Page 10: ... a chair and take 5 6 deep breaths 7 Patients with Hypertension The middle of the cuff should be at the level of the right atrium of the heart Before starting measurement please sit comfortably with legs uncrossed feet flat on the floor back and wrist supported Rest for 5 minutes before measuring Wait at least 3 minutes between measurements This allows your blood circulation to recover Take the me...

Page 11: ... press START STOP button to turn on the monitor and it will finish the whole measurement 2 Press START STOP button to power off otherwise it will turn off within 1 minute LCD display Inflating and measuring Display and save the results Adjust the zero ...

Page 12: ...d and so on During the process of displaying the results if there is no operation the blood pressure monitor will turn off in one minute Or you can press START STOP button to turn it off CAUTION The most recent record 1 is shown first Each new measurement is assigned to the first 1 record All other records are pushed back one digit eg 2 becomes 3 and so on and the last record 60 is dropped It mean...

Page 13: ...de hold pressing MEM button for 3 seconds the flash display dEL All will show 2 Press MEM to confirm deleting the LCD displays dEL dOnE and the monitor will turn off Note To exit out of delete mode without deleting any records press START STOP button before pressing MEM to confirm any delete commands 3 If there is no record the right display will show ...

Page 14: ...14 INFORMATION FOR USER Tips for Measurement Measurements may be inaccurate if taken in the following circumstances ...

Page 15: ...15 INFORMATION FOR USER Maintenance In order to get the best performance please follow the instructions below ...

Page 16: ...te the average if there are two or more pulse intervals the difference between each interval and the average is more than the average value of 25 or there are four or more pulse intervals the difference between each interval and the average is more than the average value of 15 the irregular heartbeat symbol appears on the display when the measurement results have appeared Optimal Normal High norma...

Page 17: ... throughout the day due to weather emotion exercise etc Also there is the white coat effect which means blood pressure usually increases in clinical settings Is the result the same if measuring on the right wrist It is ok for both arms but there will be some different results for different people We suggest you measure the same wrist every time What you need to pay attention to when you measure yo...

Page 18: ...en measure again E 3 shows The pressure of the cuff is excess Relax for a moment and then measure again E 10 or E11 shows The monitor detected motion while measuring Movement can affect the measurement Relax for a moment and then measure again E 20 shows The measurement process does not detect the pulse signal Loosen the clothing on the wrist and then measure again E 21 shows Measure incorrectly R...

Page 19: ... Temperature 20 C to 60 C A relative humidity range of 93 non condensing at a water vapour pressure up to 50hPa Measurement perimeter of the upper arm About 13 5cm 21 5cm Net Weight Approx 104g Excluding the batteries External dimensions Approx 85mmx67mmx23mm Exclude the cuff Attachment 2 AAA batteries user manual Mode of operation Continuous operation Degree of protection Type BF applied part Dev...

Page 20: ...ated measurement type EN 1060 3 1997 A2 2009 Non invasive sphygmomanometers Part 3 Supplementary requirements for electro mechanical blood pressure measuring systems IEC 80601 2 30 2009 A1 2013 Medical electrical equipment Part 2 30 Particular requirements for the basic safety and essential performance of automated non invasive sphygmomanometers Clinical investigation EN 1060 4 2004 Non invasive s...

Page 21: ...nfiguration in which it will be used EMC GUIDANCE Table 1 Guidance and manufacture s declaration electromagnetic emission The device is intended for use in the electromagnetic environment specified below The customer or the user of the device should assure that it is used in such an environment Emission test Compliance Electromagnetic environment guidance RF emissions CISPR 11 Group 1 The device u...

Page 22: ...ironment Surge IEC 61000 4 5 100 kHz repetition frequency line s to earth 2 kV line s to line s 1 kV 100 kHz repetition frequency line s to line s 1 kV Mains power quality should be that of a typical commercial or hospital environment Voltage dips short interruptions and voltage variations on power supply input lines IEC 61000 4 11 0 UT 0 5 cycle At 0 45 90 135 180 225 270 and 315 0 UT 1 cycle and...

Page 23: ...ommended separation distance in metres m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol NOTE 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situa...

Page 24: ...ion distance according to frequency of transmitter m 150 kHz to 80 MHz d 3 5 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 7 GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 37 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 For transmitters rated at a maximum output power not listed above the recommended separation distance d in metres m can be determined using the equation applicable to the frequency of the...

Page 25: ...25 Table 5 ...

Page 26: ...26 Table 5 cont ...

Page 27: ...country for which it was designed manufactured approved and or authorised or repair of products damaged by these modifications is not covered under this guarantee FKA Brands Ltd shall not be responsible for any type of incidental consequential or special damages To obtain guarantee service on your product return the product post paid to your local service centre along with your dated sales receipt...

Page 28: ...i Road Torch Development District Zhongshan 528437 Guangdong China MDSS Medical Device Safety Service GmbH Schiffgraben 41 30175 Hannover Germany EC REP Distributed by FKA Brands Ltd Somerhill Business Park Tonbridge Kent TN11 0GP UK Customer Support 44 0 1732 360783 I Support salterhousewares co uk ...