![Salter Brecknell B220 User Instructions Download Page 19](http://html2.mh-extra.com/html/salter-brecknell/b220/b220_user-instructions_3614174019.webp)
Changing the duration of a 'Long' press
Go to branch 29, Sub-branch 00
29.00
200
For example :
200 = 2 seconds
150 = 1½ seconds
= ½ second
50
Changing the minimum sample weight
Go to branch 61, Sub-branch 00
61.00
10
Enter the minimum sample weight in grams.
For example:
g
10
Changing the manual re-sampling range
Go to branch 61, Sub-branch 01
61.01
100
0 = Manual re-sampling off
100 - 1000 = % of initial sample size (
)
150
Changing the automatic re-sampling range
Go to branch 61, Sub-branch 02
61.02
100
0 = Automatic re-sampling off
100 - 1000 = % of initial sample size ( )
0
Changing PLUs
Branch numbers for PLUs =100 plus the PLU number.
For example: PLU 5 = 105, PLU 19 = 119.
Changing a PLU item weight
Go to PLU branch number. For example PLU5
105.00
145
Sub-branch 00
Enter the weight (g)
Sub-branch 01
Enter the number of decimal places
105.01
2
14
Summary of Contents for B220