3
Press the
On/Off/Zero
key for more than 5 seconds to turn the scale on or
off.
ZERO Function
When the scale is on, press the
On/Off/Zero
key for less than 5 seconds,
to zero the scale. Zero range is +5% of full capacity. Zero function is only
activated when there is no motion on the scale.
Pressing the
On/Off/Zero
key will also clear the active tare weight. When
the scale is at zero the
ZERO
annunciator on the left of the display, will be
lit and the
NET
annunciator will be off.
The scale will not zero if the display is 5% of full capacity. The
display will show
0------
or
0_____
, then return to the previous weight
reading.
Tare /Unit Key
Tare Function
Press the
Tare/Units
key for less than 5 seconds to tare the scale.
Tare range for this scale is up to 102% of full capacity. Wait to tare the
scale until it is stable. When a tare weight is active, the
NET
annunciator
is lit.
Unit Function
Press the
Tare/Units
key for more than 5 seconds to change the unit of
measure. Choose from lb, kg, g, oz, lb.oz,