UNPACKING
BE SURE TO REMOVE ALL PACKING MATERIAL BEFORE USE.
OPERA TING INSTRUCTIONS
Place the unit on a well
v
en
t
l
ated flat, sturdy surface away from heat
sources. This product should not be used In the Immediate vicinity of water,
such as bath tub, washbowls, swinming pool etc. where the lkelihood of
Immersion many occur.
Plug cord Into a ,rating 110V/220V AC power ouUet.
Remove the v.1re basket and set aside,
PREPARATION
1. Run towels brlelly under water.
2. Wring out excess water from the towels. Towels shoud be damp, not
soaked. You may need to wring ou1 several times.
3. Fold or roll towel and place towels In the v.1re basket. Do not overload the
wire basket or directly place towels into the towel warmer.
4. Insert the basket and towels Into the towel warmer.
5, Close the door nrmay,
6. Tum on the HEAT switch. The HEAT indica1ion lamp will remai, illuminated
while the switch Is In the
"
O
N"
posllon.
7. Tum on the UV switch, the UV indication lamp will remain a.,mina!ed while the
svdtch
Is In
the "ON" position.
{
0
•LJ
LJ-o)
CLEANING
&
MAINTENACE
Maintenance should be performed alter each day's use.
1. Tum OFF the unit by using the power switch.
2. Unplug the cord from the power oulet.
3. Wah for contents to cool before handling. Contents may be hot. Remove the
wtre basket and towels. Set the wire basket aside to dry.
4. WJih a soft cloth, wipe clown the internal surfaces. Do not use harsh
chemicals or abrasives. To dean the exterior, use a soft doth and mild soap.
5. Pull the drip tray forward and empty contents. Set the drip try aside lo dry.
REPLACING THE UV BULB
1. Tum off the unh by using the power sv.1tch
2. Unplug the cord from the power outlet
3. Screw off the faulted UV bulb,
4. Screw on a new E17/3W UV bulb, recommended wave length 240nm(UVC).
TROUBLESHOOnNG
✓
There
is
excessive moisture when the towel warmer in ON.
✓
The
towels are heating up
very
slowly,
►
Check
to
see that the towels are
oriy
slghtly damp. Excess moisture
and/or slow healing time may be a result of soaked towels.
✓
The
door is not closing properly
and/or
steam is escaping.
►
Check that
the
slcone door seal
Is
In place, Push
Into door
groove
to
assure proper fit.
UVs\,td,
_J
�
-VVlreBasket
OrtpTray
�
TOWEL WARMER
SEQ347/SEQ347K
SEQ348/SEQ348K
Power Rating
110V,60Hz or 220V,50Hz
Consumption
200W
200W
Temperature
1sa•i=-11s
°
F
158'F-176'F
Safety Device
Thermal Fuse
Thermal Fuse
Internal Dims,
10½"Wx7½"Dx5½"H
14½"Wx7½Dx9½"H
External Dims.
13¾"Wx10"Dx10-H
17¾-Wx10"Dx14"H
Capacity
24 Towels
48 Towels
UV BULB
Bulb Type
E17 (17mm c:lameter)
Power
3W
Radiation Type
UV-C. wave length 240nm
INTERNAL SURFACES. WIRE BASKETS, TOWELS ANO STEAM MAY
BE HOT. USE EXTREME CAUTION WHEN REMOVING HOT TOWELS
OR BASKETS. ALWAYS USE PROTECTIVE HEAT RESISTANT
GLOVES OR MITTS TO AVOID STEAM OR OTHER BURNS. FAILURE
TO HEED WARNINGS MAY RESULT IN HARM OR SERIOUS INJURY,
Sa
l
o
ns
e
rv
e
H
a
ir
& Beauty
S
upp
l
i
es
Le
x
i
con
H
ous
e
,
Station Road
..
l
rth
l
i
n
gboro
ug
h
,
No
rt
h
ants
,
NN9 5QF
0
1
933 410 022
www
.so
l
ons
erve
.com