16
SALMSON 09/2014
5. Product information
5.1 Type key
5.3 Scope of delivery
Pump with
• 10 metre connecting cable with mains plug
• Connected float switch (design-F)
• Turbulator (Systéme SAN)
• Hose connection (Ø 32 mm / R 1)
• Non-return valve
• Installation and operating instructions.
5.4 Accessories
Accessories must be ordered separately (see
catalogue):
• Switchgear for 1 or 2 pump operation
• External monitoring devices / tripping unit
• Level control (e.g. flow switch)
• Accessories for transportable wet sump installa-
tion (e.g. hose couplings, hoses, etc.).
• Accessories for stationary wet sump installation
(e.g. check valves, non-return valves, etc.).
5.2 Technical data
Mains voltage:
1~230 V, ± 10 %
Mains frequency:
50 Hz
Protection class:
IP 68
Insulation class:
B
Speed:
2900 rpm (50 Hz)
Max. current consumption:
See name plate
Power consumption P1:
See name plate
Max. flow rate:
See name plate
Max. delivery head:
See name plate
Operating mode:
4000 operating hours a year
Operating mode S3 (optimum):
Intermittent duty, 30 %
(3.0 min. operation, 7.0 min. interval).
Recommended switching frequency:
20/h
Max. switching frequency:
50/h
Free ball passage:
10 mm
Nominal diameter of the pressure port:
Ø 32 mm (Rp 1¼)
Admissible fluid temperature:
briefly 3 min.:
+3 to 35 °C
90 °C
Max. submersion depth:
10 m
Flat suction up to:
18 mm
English
Example: SUBSON Premium 20 MFP
SUBSON
Submersible pump
Premium
Stainless steel
20
Size
M
Single-phase
F
With float switch
P
« portable » version with 10 metre cable
Summary of Contents for SUBSON Premium
Page 38: ...Notes...
Page 39: ...Notes...