38
05/2017
en
7.2
Setting the control mode and the delivery head
The size of the dots and data for setting the delivery
head are provided as a guide only.
A more detailed calculation for the setting is recom-
mended. The values of the delivery head are displayed in
increments of 0.1 m with the setting.
Radiator heating
system
Variable differential pressure (
Δ
p-v):
• Select the setting range of the application.
• Set setpoint H of the delivery head (variable differen-
tial pressure).
The LED display shows the setpoint H of the delivery
head in
m
.
Underfloor heating
Constant differential pressure (
Δ
p-c):
• Select the setting range of the application.
• Set setpoint H of the delivery head (constant differ-
ential pressure).
The LED display shows the setpoint H of the delivery
head in
m
.
H+
H-
Pump
Number of radiators
Priux home M 40
8
12
15
Priux home M 60
12
15
20
Priux home M 80
15
20
30
H+
H-