5 Product information
5.1 Type key
5.3 Scope of delivery
• Acson Vario prewired (fig. 2, Pos. 2)
• EMC filter (fig. 2, Pos. 6)
• Operating instruction
5.4 Accessories
5.4.1 Accessories required
• A tank of minimum 2 liters (to be placed at the Acson Vario discharge side, see
fig. 2, Pos. 4).
• Check valve (to be placed directly at the Acson Vario suction side, see fig. 2, Pos.
3).
5.4.2 Accessories as option
• Flow switch - dry running protection.
• Insulation valves.
6 Description and Function
Example : Acson Vario VST 10A
Acson Vario
Automatism type with frequency inverter
VS
Electrical supply of the Acson Vario
1~230V
T
Electrical supply of the motor
• T = 3~230V
• M = 1~230V
10
Maximal current delivered by the Acson Vario
5.2
Technical data
Maximum operating pressure
MM5 & MT6 : 10 bar
MM9 & MT10: 15 bar
Setting range
0.5 up to 12 bars
Maximum flow
15 m³/h
Maximum water temperature
40 °C
Minimum water temperature
0 °C
Maximum environment temperature
50 °C
Input voltage
1~230 V, 50/60 Hz
Protection current
+20% of the nominal current as set during 10s
Operating mode
S3: 30% (3 s ON – 7 s OFF)
Class of protection
IP55
Protection fuse of the Acson Vario
input (fig. 4, Pos. 3)
I: 20A, type: gG, U: 500Vac,
breaking capacity I1: 120kA, size: 10 x 38mm