Salicru SPS.HOME User Manual Download Page 11

11

7.  ANNExES.

7.1.  Technical sPecificaTions.

Models.

SPS.650.HOME

SPS.850.HOME

Power.

650 VA / 360 W

850 VA / 490 W

Technology.

Off-Line.

Input.

voltage.

220.. 240 v AC single-phase.

voltage range.

180.. 270 v AC

frequency.

50 / 60 hz auto-detectable.

number of power cables.

3 (phase + neutral and earth connection) with plugs.

Output.

Rated voltage.

230 v AC single-phase.

voltage accuracy.

±7 %

frequency.

50 (60) hz

output frequency accuracy.

±1 %

waveform.

Pseudo sine wave.

Typical transfer time.

4 ms

Compatibility with APfC loads.

yes

electronic protection.

Power overload, short circuit, battery overload and discharge.

overload in line mode.

> 110%, output voltage cut after 1 min; > 200%, output voltage cut immediately.

overload in battery mode.

> 100 %, output voltage cut after 1 min; > 120 %, output voltage cut immediately.

output sockets.

6 (4 for powering critical loads - battery mode - and 2 direct from mains with protection against power surges).

Battery.

element rated voltage.

12 v dC (Pb-Ca sealed, maintenance-free battery).

number of elements / Capacity.

1 / 5 Ah

1 / 5.6 Ah

Typical recharge time.

8 hours to 90% charge.

Optical and audible indication.

Surrounding the on-off button.

Led.

Indications.

normal operation mode, mains failure, end of backup, overload.

Audible alarm.

battery mode: beep every 30 sec.

Low battery: beep every 0.5 sec.

overload: continuous beep.

failure: continuous beep.

Physical.

maximum dimensions (depth × width × height).

316 (with power cable included 336) x 121 x 93 mm.

weight.

2.7 kg

3.0 kg

Protection rating.

IP20

Total output sockets.

6

output sockets for critical loads + overvoltage 

protection.

4

output sockets with overvoltage protection.

2

Environmental.

operating temperature.

0.. 40ºC

Relative humidity.

0.. 90% non-condensing.

Interface, communication and management.

USb (hId).

yes

Phone line/AdSL protector.

yes

Power master software.

windows 8 / 7 / vista / XP / 2000 / Server 2003, Linux.

battery self-charging.

yes

Auto start after mains failure.

yes

Tab. 3. 

Technical specifications.

SPS HOME

 UnInTeRRUPTIbLe PoweR SUPPLy (UPS)

USER'S MANUAL        

Summary of Contents for SPS.HOME

Page 1: ...SPS HOME USER S MANUAL UNINTERRUPTIBLE POWER SUPPLY UPS...

Page 2: ...2 SALICRU...

Page 3: ...ntents 5 2 Siting and considerations 5 2 1 Siting 5 2 2 Considerations 5 2 2 1 Battery charging 5 2 2 2 Power connected to the SPS HOME 5 3 Connection and commissioning 5 3 1 Procedure to follow 5 3 1...

Page 4: ...by qualified personnel Although no effort has been spared to ensure that the in formation in this user manual is complete and accurate we are not responsible for any errors or omissions that may exist...

Page 5: ...for the correct identification of each of the parts which together with the in structions described in this user manual allows the operations of installation and commissioning to be performed in a sim...

Page 6: ...UPS Part 1 1 General and safety requirements for UPS used in user access areas EN IEC 60950 1 Information technology equipment Safety Part 1 General requirements EN IEC 62040 2 Uninterruptible power s...

Page 7: ...perform this task of protection against mains failures by providing a similar voltage for a period of time Under normal conditions the output of the UPS is the same as the input of the AC power mains...

Page 8: ...will charge irrespective of whether the SPS HOME is switched on or off 5 2 2 2 Power connected to the SPS HOME Check that the loads connected to the power sockets do not exceed the power rating of th...

Page 9: ...ted beep every 0 5 sec for moderate overload or continuous for excessive Normal Tripped Overload Activated by excessive load connected to the device s output sockets Stop the UPS disconnect the load A...

Page 10: ...o load connected to prevent a mains failure from discharging the battery and leaving the loads unpowered Unit has been damaged by a repetition of voltage peaks Contact distributor or seller and failin...

Page 11: ...er surges Battery Element rated voltage 12 V DC Pb Ca sealed maintenance free battery Number of elements Capacity 1 5 Ah 1 5 6 Ah Typical recharge time 8 hours to 90 charge Optical and audible indicat...

Page 12: ...alicru_SA Product Range Uninterruptible Power Supplies UPS Lighting Flow Dimmer Stabilisers DC Power Systems Static Inverters Photovoltaic Inverters Voltage stabilisers Variable frequency drives The T...

Reviews: