Salicru NIMBUS User Manual Download Page 4

4

1.  PRODUCT OVERVIEW.

1.1.  VIEWS

Fig. 1. 

View of the NIMBUS card 

Description

Function

1

 

COM1 port

Serial interface to connect the card to other 

devices using a mini USB cable.

2

 

COM2 port

Serial interface to connect the card to other 

devices using a USB cable.

3

 

RS-232 port

Serial interface to connect the card using the 

RS-232 protocol.

4

 

RS-485 port

Serial interface to connect the card using the 

RS-485 protocol.

5

 

RJ-45 port

10/100Mbit Ethernet interface.

6

 

External DC input

Powered by a 5V adapter.

7

 

Modbus port

Serial interface for modbus communication 

with the device. Powers the card internally.

8

 

Power LEDs

Turned on when the card is powered with the 

DC input (internal or external).

9

 

RTC

Real-time clock to keep the time of the card 

updated in case of mains failure.

10

 

HDMI port

HDMI interface to connect the card using an 

HDMI micro cable.

11

 

MicroSD connector

Enables the NIMBUS card version to be 

updated using a MicroSD.

12

 

Display connector

Connector for flat bus cable to connect the card 

to an LCD.

Tab. 1.  Description of the constituent parts

1.2.  DESCRIPTION OF THE SYSTEM

1.2.1.  Introduction

The 

SALICRU

 devices are usually installed in locations far away 

from the area of production, which means that information pro-

vided by the device about its status can often be overlooked. 

The 

NIMBUS

 card solves this problem by offering a remote 

maintenance service that provides real-time information about 

the current status of the device.

Remote communication with the device enables maintenance 

and repair work to be carried out without the need to travel to 

the installation site to find out about its status.

The functionalities of the NIMBUS card are specially designed 

to work with SALICRU devices, making it currently compatible 

with the following series:

 

DC POWER-S

 

DC POWER-L

 

SLS CUBE3 / CUBE3+

 

SLC CUBE4

 

EMI3

 

SLC ADAPT/X

 

SLC ADAPT2

 

SLC X-PERT

1.2.2.  Features of the system

The NIMBUS card features various basic integrated services to 

enable basic connection to the device.

Basic service

Description

Onboard panel

Web panel that enables remote monitoring of the 

device. As it is dependent on the NIMBUS card, if it 

is not connected, it will not be possible to access the 

panel.

Communication 

through MODBUS

Reading data through MODBUS.

Communication 

through MODBUS 

TCP

Reading data through MODBUS TCP.

Communication 

through SNMP

Reading data and reception of alarms through SNMP.

RTC

The card’s internal real-time clock.

Auto-

configuration of 

the device

When installing the card in any of the compatible 

devices, it will automatically detect which device it is.

Alarm 

notification

Notification alert through the onboard panel in real 

time.

DNS server

Possibility of assigning domain names to the device.

IP address

Choice of DHCP or static web address.

RCCMD

Enables remote shutdown of the designated clients 

and servers under certain conditions. 

Tab. 2.  Basic integrated services

Summary of Contents for NIMBUS

Page 1: ...USER MANUAL NIMBUS Card...

Page 2: ...2...

Page 3: ...only for Administrator and Engineer users 3 5 3 1 ADAPT X Series 3 5 3 2 CUBE3 CUBE3 Series 3 5 3 3 X PERT Series 3 5 3 4 DC S Series 3 5 4 Metrics 3 5 5 Manage alarms DC S series only 3 5 6 Actions D...

Page 4: ...remote maintenance service that provides real time information about the current status of the device Remote communication with the device enables maintenance and repair work to be carried out withou...

Page 5: ...o offers the possibility of receiving notification alerts whenever an event or alarm occurs in the device either through the same web page or via email The remote maintenance with the web panel also o...

Page 6: ...available IP address must then be correctly configured in order to gain remote access to the card s onboard panel 2 1 1 Point to point connection Ethernet cable The fixed IP is always available at th...

Page 7: ...s It is only necessary to import the certificate once with any of the browsers The system will save the certifi cate for all of them If the certificate has already been imported into the computer and...

Page 8: ...t A screen similar to the one shown in Fig 10will appear Click on Import Fig 10 Import window The system will require the password of your computer before proceeding When prompted for the label enter...

Page 9: ...message will no longer be displayed Fig 14 Accept risk and continue window 3 1 1 3 Chrome Opera The first time you access the panel the following screen will be displayed Fig 15 Chrome Opera browser...

Page 10: ...g 19 Fig 19 Certificate viewer screen Once this step is finished the certificate will have been imported correctly Restart the browser to confirm it In Settings navigate to the bottom of the page acce...

Page 11: ...IP field you will find the address to enter in the browser 3 If the card does not have a static address it will be as signed one automatically as soon as you connect the RJ45 cable 3 1 3 Supported bro...

Page 12: ...e other options will be shown To avoid long navigation trees which can lead to confu sion only one overall section at a time can be displayed Within the section Device you can continue to display the...

Page 13: ...active and shows no errors For the battery full charge Yellow only for the battery The battery is in discharge or the charge is less than 100 Grey No current is flowing through that element or part of...

Page 14: ...29 Diagram relating to a single module 3 4 2 Alarms At the bottom of the screen the different blocks of alarms that the device has and its current status are shown block 3 Non active alarms are shown...

Page 15: ...odify only the non critical parameters of the device Important For some devices it is not possible to modify certain parameters if the required circumstances are not met Refer to section 3 5 3 x for m...

Page 16: ...knowledged again 3 5 6 Actions DC S series only In this section it is possible to force actions on the device al though at present only the battery test is available When it is possible to launch an a...

Page 17: ...u must first refer to the section 4 In stalling the RCCMD software Specify the IP address of the destination server here If you wish to broadcast enter the broadcast IP You must also add the port of t...

Page 18: ...in order to read information as well as the parameters of the protocol for establishing a connection to the device By default these values already enable correct communication with the device If you w...

Page 19: ...HE SOFTWARE Open a browser window and go to https www generex de From there click on the Download tab and make sure that below the Software section there is a section titled RCCMD Now click on the but...

Page 20: ...elected this operating system you will need a li cence code which will be provided by SALICRU Once you have the code and have selected the desired oper ating system click on the Create package button...

Page 21: ...e NIMBUS card To enter an IP click on the Insert button as shown in the image A pop up window will appear as shown in Fig 56 Fig 56 Insert IP screen In the corresponding field enter the IP of the NIMB...

Page 22: ...IN THE CLOUD There are two ways to register the device in the cloud using the portal and using a QR code 5 1 1 Nimbus portal 1 Go to https nimbus salicru com 2 To register the product you will need t...

Page 23: ...y if you have registered other SALICRU devices you can use this field to easily differentiate between them The device s location and the corresponding time zone are both obligatory fields To add the d...

Page 24: ...Remember to check the Spam folder if you cannot find the email in your inbox After you click on the link contained in the email you will be able to create a new password Click on Save to save changes...

Page 25: ...essage similar to the one below will appear and the new device will be added to your list of registered devices 5 2 GENERAL TECHNICAL SPECIFICATIONS In the Tab 6 below lists the technical specificatio...

Page 26: ...26...

Page 27: ...27 NIMBUS Card USER MANUAL...

Page 28: ...com SALICRU COM www linkedin com company salicru salicru_SA Product Range Uninterruptible Power Supplies UPS Stabilisers Step Down Light Dimmers Power Supplies Static Inverters Photovoltaic Inverters...

Reviews: