Connect the AC connector to the inverter's AC terminal;
a click indicates that the connection is in place, as shown
in Fig. 31:
Fig. 31. Connecting the AC connector to the inverter's AC terminal.
f.
Insert the relevant AC circuit breakers in between,
as shown in the table below:
Model
Thermal-
magnetic
circuit
breaker
Differen-
tial relay
Over-
voltage
protection
Previous
fuse. Max.
value
(1/phase)
EQX2 2001-S
2P 16A
Curve C
2P 25A
30mA
Class A
40kA 230V
TT Type II
125 A gL
EQX2 3001-S
2P 20A
Curve C
EQX2 3002-S
EQX2 3002-SX
EQX2 4002-S
2P 32A
Curve C
2P 40A
30mA
Class A
EQX2 4002-SX
EQX2 5002-S
2P 40A
Curve C
EQX2 5002-SX
EQX2 6002-S
EQX2 6002-SX
EQX2 8002-SX
2P 50A
Curve C
2P 63A
30mA
Class A
EQX2 10002-SX
2P 63A
Curve C
Tab. 10. AC circuit breakers
g.
Connect the other end of the hose to the AC circuit breaker
in the junction box, downstream of the connection's IGA.
L
N
Fus.
SPD
IGA
GND
MCB
Inverter
ID
ID
PIAs
Fig. 32. Electrical wiring diagram.
For the connection of equipment with 24h monitoring, see
manual EL23300.