Salicru EQUINOX EQX 5000-2T Quick Manual Download Page 5

5

QUICK GUIDE

EQUINOX

  -  SOLAR INVERTERS

2.  MECHANICAL INSTALLATION.

2.1.  POSITIONING THE DEVICE

If you are installing the optional ESM3T EQX energy meter, we recommend installing the inverter as near to the electrical connection 

as possible, in order to avoid extending the RS485 communications cable.

Angle and spacing of the installation

: Make sure the device is installed on a vertical surface and that the following minimum safety 

distances are maintained with regard to other elements, in order to ensure optimum ventilation:

Dimension

Distance (mm.)

A

500

B

400

Wall mount:                       

~

 10 kW

Model

A (mm)

B (mm)

Ø (mm)

Drill depth  

(mm)

Tightening torque 

(Nm)

EQX 5000-2T

260

45

8

50

13

EQX 8000-2T

EQX 10000-2T

Summary of Contents for EQUINOX EQX 5000-2T

Page 1: ...EQX 5000 2T EQX 8000 2T EQX 10000 2T SOLAR INVERTERS QUICK GUIDE...

Page 2: ...2 SALICRU...

Page 3: ...3 ELECTRICAL INSTALLATION 3 1 DC DIRECT CURRENT INSTALLATION 3 2 AC ALTERNATING CURRENT INSTALLATION 3 3 JUNCTION BOX 4 ON OFF SEQUENCE 5 OPERATION USING THE DISPLAY 5 1 DISPLAY 5 2 PARAMETERS MENU 5...

Page 4: ...ount 1 4 Metal bolt only for concrete walls 4 5 Fixing screws 2 6 POSITIVE DC connector set and terminal 2 7 NEGATIVE DC connector set and terminal 2 8 AC connector 1 9 RS485 communications connector...

Page 5: ...der to avoid extending the RS485 communications cable Angle and spacing of the installation Make sure the device is installed on a vertical surface and that the following minimum safety distances are...

Page 6: ...6 SALICRU Mounting process Material required Steps to follow...

Page 7: ...and that there is no voltage in the cables you are going to handle DC Connecting the solar park cables Material required 1 Unscrew the MC4 connectors supplied and prepare the cables coming from the ju...

Page 8: ...um tightening without damaging the connectors 5 Check the polarity and voltage of the photovoltaic panels before connecting them to the inverter in line with the values shown in the following table Sp...

Page 9: ...t lengths If the facility s solar panels are not on the same level i e they are exposed to different levels of radiation whether due to the shape of the roof differences in inclination or different st...

Page 10: ...trings that can be connected to each MPPT depending on the device model Model String MPPT EQX 5000 2T 1 2 EQX 8000 2T 1 2 EQX 10000 2T 1 2 3 2 AC ALTERNATING CURRENT INSTALLATION Make sure the protect...

Page 11: ...minals at the ends of the cables 3 Insert and screw the cables to the corresponding terminals on the connector R phase S phase T phase and earth G Once this is done pull gently on the cables to make s...

Page 12: ...1000 VDC 15 A string Type II 40 kA 1000 VDC Type I II 5 kA 1000 VDC EQX 8000 2T Built into the device Fuses 1000 VDC 15 A string Type II 40 kA 1000 VDC Type I II 5 kA 1000 VDC EQX 10000 2T Built into...

Page 13: ...13 QUICK GUIDE EQUINOX SOLAR INVERTERS Example of a junction box with DC protections on the left and AC protections on the right...

Page 14: ...ply the device will not enter generation mode AC DC 4 The device will start up The LCD screen will turn on The following section details the steps to follow and explains how the console works Follow t...

Page 15: ...tings menu the language selection and the country of installation 5 2 PARAMETERS MENU Your new EQUINOX solar inverter comes pre configured to comply with the current Spanish regulations Therefore you...

Page 16: ...00 x1 Cur EUR Va l 0 1 00 x2 Cur EUR Va l 0 1 20 x2 Setup Cash Setup Cash Setup Cash Setup Cash Setup Cash Setup Cash Setting the date and time Go back to the Settings menu If you are already on a men...

Page 17: ...09 Date Time Time 16 45 00 x1 Fecha 09 03 2025 Fecha Hora Hora 16 45 00 x15 Changing the MPPT model By default the device is configured to connect 2 MPPTs To change the configuration to 1 MPPT go to t...

Page 18: ...nd DOWN ARROWS to enter the number of your choice Press ENT again to confirm the number and the line will then move on to the next number on the right The example below shows how to enter the password...

Page 19: ...h Duch Country Spain Germany UK Aus_default Belgium Denmark Holland Thailand Singapore Italy New Zealand Aus_Standard Power Settings Export P Set Lim Inv P Power Factor Gr Ti Mode Factor Set Model 2 M...

Page 20: ...ncy Possible fan malfunction Fault The inverter interrupts generation and goes into sleep mode due to anomalies in the mains or power supply Insufficient DC input voltage Mains undervoltage or overvol...

Page 21: ...s voltage high E004 Boost Fail Voltage step up malfunction E005 Grid OC Internal AC overcurrent E006 OTP The inverter s internal temperature is too high E007 Lo Iso R Isolation impedance low E008 IGBT...

Page 22: ...AND INSTALLING THE APP ON YOUR SMARTPHONE Download the EQX sun app from either the Play Store Android or App Store iOS depending on your smartphone s operating system After you have downloaded the ap...

Page 23: ...23 QUICK GUIDE EQUINOX SOLAR INVERTERS...

Page 24: ...a Serra 100 08460 Palautordera BARCELONA Tel 34 93 848 24 00 sst salicru com SALICRU COM www linkedin com company salicru salicru_SA Product Range Uninterruptible Power Supplies UPS Stabilisers Step D...

Reviews: