background image

EN |

 17

KF T120_KF T120 EC v2019.04 

WARRANTY

1. All equipment manufactured in our factory is checked in operating conditions and tested befor delivery. Test protocol is supplied together with 

the unit. The equipment is shipped in good working order and condition to the direct client. The unit is warrantied for the period of two years from 

the invoice date.

2. If equipment is found to have been damaged during transportation, a claim should be made against carrier, as we assume no responsibility for 

such damage.

3. This warranty does not apply:

3.1. when transportation, storage, installation and maintenance instructions of the unit are violated;

3.2. when the equipment is improperly maintained, mounted - inadequate maintenance; 

3.3. when the equipment without our knowledge and permission has been upgraded or unskilled repairs were made;

3.4. when the unit was used not for its original purpose.

3.5. Company SALDA UAB is not responsible for potential loss of property or personal injury in cases where AHU is manufactured without a con

-

trol system and the control system will be installed by the client or third parties. The manufacturer’s warranty does not cover devices that will be 

damaged by installing the control system.

4. This warranty does not apply at these malfunction cases:

4.1. mechanical damage; 

4.2. damage caused by entering outside objects, materials, liquids; 

4.3. damage caused by natural disaster, accident (voltage change in the electricity network, lightning, etc..).

5. The company assumes no liability for its products either directly or indirectly damage, if the damage is caused by failure to comply with instal

-

lation and mounting regulations, deliberate or careless users or third-party behavior.

These conditions are readily discernable when the equipment is returned to our factory for inspection.

If the direct client determines that equipment is found to be faulty, or a breakdown occurred, he should inform the manufacturer within five working 

days and deliver the equipment to manufacturer. Delivery costs should be covered by customer.

Manufacturer reserves the right to change this technical passport any time without prior notice, if some typographic 

errors or inaccurate information is found, as well as after improving the apps and/or the devices. Such changes will be 

included in the new issues of the technical passport. All illustrations are just for information and thus may differ from the 

original device.

20.1. LIMITED WARRANTY COUPON

Warranty term

24 months*

I received complete package and technical manual of the product ready for usage. I have read warranty terms and conditions and agree with them: 

 

..........................................................................................................................................................................

Customer’s signature

*refer to WARRANTY CONDITIONS

D

ear User, we appreciate your choice and do hereby guarantee that all ventilation equipment manufactured by our Company is inspected and 

thoroughly tested. An operational and high-quality product is sold to the direct buyer and shipped from the territory of the factory. It is provided with 

a 24-month warranty since invoice issue date.

Your opinion is important to us, thus we always look forward to hearing your comments, feedback, or suggestions regarding technical and opera

-

tional characteristics of the Products.

In order to avoid any misunderstandings, please read the instructions for installation and operation of the product as well as other technical docu

-

ments of the product carefully. The number of the Limited Warranty Coupon and serial number of the product specified on the silver identification 

sticker attached to the housing must match. 

The Limited Warranty Coupon shall be valid provided that the seller’s stamps and records are clear. It is prohibited to change, delete, or rewrite 

the data specified on it in any manner – such a coupon shall be invalid.

With this Limited Warranty Coupon the manufacturer confirms one’s obligations to implement the imperative requirements established by effective 

laws on protection of consumer rights in the event of identification of any defects of the products.

The manufacturer reserves the right to refuse provision of free warranty servicing in cases when the warranty conditions listed below are disre

-

garded.

Summary of Contents for KF T120 Series

Page 1: ...KF T120 KF T120 EC EN MOUNTING AND INSTALLATION INSTRUCTION...

Page 2: ...ly by trained and qualified staff familiar with this type of equipment installation verification mainte nance and required tools for installation works Make sure that all the warning signs on the fan...

Page 3: ...548 407 250 196 500 29 225 4L3 161 131 537 305 253 250 250 80 50 597 456 277 222 500 34 250 4L3 170 146 577 342 278 315 315 90 50 651 500 290 236 620 44 280 4L3 180 153 626 367 304 315 315 90 50 688 5...

Page 4: ...26 b SP27 b KF T120 160 4 L3 180 4 L3 200 4L3 225 4L3 phase voltage 50 Hz VAC 3 400 50 3 400 50 3 400 50 3 400 50 power kW 0 18 0 29 0 54 0 92 current A 0 57 1 0 1 44 1 72 speed min 1 1310 1340 1390 1...

Page 5: ...er flange 2 Hinges 3 Housing 4 Anti vibration feet 5 Connection Ring 6 Fan 7 Fat chutes with a plug 1 2 8 Switch 9 Roof 10 Engine 11 Electrical connection box 12 Feet 13 Panel bushings 14 Handle Avail...

Page 6: ...STORAGE All units are packed in the factory to withstand regular conditions of transportation Upon unpacking check the unit for any damages caused during transportation It is forbidden to install dam...

Page 7: ...T120 EC Control Accessories 1 MTP010 regulator 2 Stouch panel 3 Stouch S 1141 Domestic use installed filters box For industrial use filters installed extractors Exhaust air Kitchen hood AB AGO ALU Mo...

Page 8: ...tor cools down and connected capacitors when used discharge Ensure that the fan and installed parts and accessories are firmly and tightly installed Carefully clean the impeller to avoid changing the...

Page 9: ...rical connection box The fan has to be connected according to the electric scheme which is described in this document and is shown under the electricity connection switch cap Before turning on it is n...

Page 10: ...L3 2 1 1 2 1 2 2 1 3 2 1 4 2 1 5 2 W1 gr ye W1 black W1 brown W1 grey W3 1 W3 2 W2 1 W2 2 W2 3 PE 1 L1 2 L2 3 L3 3 NC 2 COM 4 Ain1U 0 10V 3 GND 5 10V M1 SP27 b Black 0 5 Black 0 5 Black 0 5 Black 0 5...

Page 11: ...6 PE 1 PE 2 1 2 3 4 5 6 F2 L3 1 2 3 4 5 6 K2 L3 L1 L2 1 2 3 4 5 6 F2 K K2 1 2 3 4 5 6 Q2 1 2 3 4 5 6 PE PE 1 L2 2 L2 1 PE 2 PE SP27 b 1 L1 2 L1 N N With speed controller SMT D 4P EL which allows to se...

Page 12: ...4 PE L1 N K1 A1 A2 K1 1 2 3 4 F1 1 2 10V 1 5 2 1 L1 2 1 1 2 1 2 2 1 3 2 1 4 2 1 PE 2 1 N 2 PE N L1 GND NC COM SP26 b SP25 b 0 10V PE Q1 1 2 3 4 5 6 Vout GND SMT D 4P EL Vin max 1 1mA GND 1 2 3 4 N L1...

Page 13: ...e the launching Make sure that all the bolts and nuts are tightened before the launching MAINTENANCE SAFETY REQUIREMENTS Installation works can only be performed by trained and qualified personnel The...

Page 14: ...balance ant the specialized company Adhesions on the impeller Clean carefully rebalance if necessary Material decomposition on the impeller due to aggressive material conveyed Contact the manufacturer...

Page 15: ...e electrical connection according presented connection scheme Temperature indicator has responded Allow the motor to cool down find and elim inate the cause release reactivation lock if applicable Ele...

Page 16: ...ment and risk reduction LST EN 60204 1 Safety of machinery Electrical equipment of machines Part 1 General requirements LST EN 60335 1 Household and similar electrical appliances Safety Part 1 General...

Page 17: ...the equipment to manufacturer Delivery costs should be covered by customer Manufacturer reserves the right to change this technical passport any time without prior notice if some typographic errors o...

Page 18: ...18 KF T120_KF T120 EC v2019 04...

Page 19: ...19 KF T120_KF T120 EC v2019 04...

Page 20: ...000211 UNIT S MAINTENANCE TABLE Product name lot number Instalation Interval Date Fan cleaning Once a year Heat exchanger cleaning Once a year Filter replacement Every 3 4 months Look at the product l...

Reviews: