background image

   

   

9

   

GAS SALAMANDER GRILL 

 

   

   

   

Kasap Tip Dik Buzdolapları 

 
 
 

 

INJECTOR CHANGE AND GAS SETTING

 

GAS VAPOR GRILL BURNER-INJECTOR CHANGE CHART 

Gas 
Group 

Gas 

PSG.3 

PSG.4 

PSG.5 

PSG.6 

Injector 

 

mm 

Injector 

 

mm

 

Injector 

 

mm 

Injector 

 

mm 

G20 

1,40 

1,40 

1,40 

1,40 

G25 

1,40 

1,40 

1,40 

1,40 

G30 

30  

50  

G31 

37  

50  

  

 

Change of Burner Injector; 

1.  Rip off the injector at the entrance of burner with a suitable tool. 
2.  Change A  injector  by paying attention to the datas at chart  with suitable injector. 

(Image 1) 

3.  Adjust the burner entrance setting (F) by loosening  ‘B’ bolt and moving the  valve to 

forward-back. (Image 2) 

4.  Change C   injector  by paying attention to the datas at chart  with suitable injector.For 

this it is enough  to take off   ‘D’ fitting and pull the gas  pipe to down. (Image 3) 

 
 

Setting of Half Flame; 

1.  Remove the tap button and set by turning  tap half flame screw (K) with suitable 

screwdriver.(Image 4) Turn it to left  for transformation from LPG to N.G,turn it right for 
transformation from N.G to LPG. 

2.  After this process,operate the appliance and set it not to be deflated  during transition 

from full flame to half flame.

 

 
 
 
 
 
 
 
 

Summary of Contents for EMP.PSG.3

Page 1: ... A2 TECHNICAL INFORMATION Page 3 A3 TRANSPORTATION Page 3 A4 UNPACKING Page 4 B INSTALLATION Page 4 C SAFETY INSTRUCTIONS Page 5 D OPERATION Page 6 E CLEANING MAINTENANCE Page 7 F TROUBLESHOOTING Page 8 G INJECTOR CHANGE AND GAS SETTING Page 9 H GAS CONNECTION IMAGES Page 10 I SPARE PART LIST EXPLODING DRAWING Page 12 ...

Page 2: ...f disobeying instructions and regulations wrong connections Unauthorized intervention to appliance invalidates the warranty 1 This instruction manual should be kept in a safe place for future reference 2 Installation should be made in accordance with ordinances and security rules of that country by a qualified service personnel 3 This appliance has to be used by trained person 4 Please turn off th...

Page 3: ...50 EMP PSG 4 970x440x600 50 1100x530x750 EMP PSG 5 1105x440x600 59 1000x510x720 EMP PSG 6 1240x440x600 67 1340x530x710 A2 TECHNICAL INFORMATION Product Code Model Power KW Gas Consumption NG Gas Consumption LPG EMP PSG 3 3 Burners 8 1 m h 0 7 kg h EMP PSG 4 4 Burners 11 1 3 m h 0 9 kg h EMP PSG 5 5 Burners 14 1 6 m h 1 1 kg h EMP PSG 6 6 Burners 17 1 9 m h 1 4 kg h A3 TRANSPORTATION This appliance...

Page 4: ...appliance is must have enough ventilation and vent hole The appliance must be connected correctly according to local and national gas standards of your country The appliance gas entrances are indicated with G label on the body Connection to gas fitment must be done with suitable diameter metal flex pipe and spheric valve The spheric valve must be immobilized to a place that is far away from heat a...

Page 5: ...more than appliance s capacity Do not attempt to use the appliance without suitable protective equipments Because of any reason if there is a fire or flame flare where the appliance is used turn off all gas valves and electric contactor switch quickly and use fire extinguisher Never use water to extinguish the fire If there is gas leakage where the appliance is do not fire absolutely and do not us...

Page 6: ... during first operation Press the gas grill button and provide pilot position Fire the pilot with suitable lighter In order to heat thermocouple s end keep pressing to button after the pilot is fired For desired temperature switch to half or full flame position Operate the grill when it is empty to remove protective oil Add water to moving lower tray In this way the meats that are cooked at grill ...

Page 7: ...ce with a materials that may damage chrome material Clean the grills with suitable spatula Ø PERIODIC CLEANING AND MAINTENANCE Maintenance should be done by qualified person These parts Gas storage pilot thermocouples taps burner lighter and spark plug cable are not maintained so they need to be changed when they have error Check the gas connection hoses in periodic time If there is slit hole etc ...

Page 8: ...gas setting or not 2 If there is not enough water at lower tray then add some THE APPLIANCE STOPPED 1 Gas flow is stopped automatically when the flame is off due to having gas tap that has safety valve In this situation the appliance is not operated 2 When there is gas leakage if there is solenoid gas stopper alarm gas flow is stopped and the appliance is not operated Ventilate the area through th...

Page 9: ...he datas at chart with suitable injector Image 1 3 Adjust the burner entrance setting F by loosening B bolt and moving the valve to forward back Image 2 4 Change C injector by paying attention to the datas at chart with suitable injector For this it is enough to take off D fitting and pull the gas pipe to down Image 3 Setting of Half Flame 1 Remove the tap button and set by turning tap half flame ...

Page 10: ... 10 GAS SALAMANDER GRILL Kasap Tip Dik Buzdolapları H GAS CONNECTION IMAGES Image 2 Image 1 ...

Page 11: ... 11 GAS SALAMANDER GRILL Kasap Tip Dik Buzdolapları H GAS CONNECTION IMAGES Image 3 Image 4 ...

Page 12: ... 12 GAS SALAMANDER GRILL Kasap Tip Dik Buzdolapları I SPARE PART LIST EXPLODING DRAWING EMP PSG 3 ...

Page 13: ... 13 GAS SALAMANDER GRILL Kasap Tip Dik Buzdolapları I SPARE PART LIST EXPLODING DRAWING ...

Page 14: ... 14 GAS SALAMANDER GRILL Kasap Tip Dik Buzdolapları I SPARE PART LIST EXPLODING DRAWING EMP PSG 4 ...

Page 15: ... 15 GAS SALAMANDER GRILL Kasap Tip Dik Buzdolapları I SPARE PART LIST EXPLODING DRAWING ...

Page 16: ... 16 GAS SALAMANDER GRILL Kasap Tip Dik Buzdolapları I SPARE PART LIST EXPLODING DRAWING EMP PSG 5 ...

Page 17: ... 17 GAS SALAMANDER GRILL Kasap Tip Dik Buzdolapları I SPARE PART LIST EXPLODING DRAWING ...

Page 18: ... 18 GAS SALAMANDER GRILL Kasap Tip Dik Buzdolapları I SPARE PART LIST EXPLODING DRAWING EMP PSG 6 ...

Page 19: ... 19 GAS SALAMANDER GRILL Kasap Tip Dik Buzdolapları I SPARE PART LIST EXPLODING DRAWING ...

Reviews: