Salamander Pumps TankBoost Series Installation And Warranty Manual Download Page 7

Control Unit Display Codes

Display Code

Description

System Reaction

A01

Dry Running

If water level in the tank is low (less than half way up the 

pump), allow the tank to refill and manually restart the unit 

by pressing the power/enter button.

This error code indicates that the unit will enter into 

protective shut down to protect the pump.

To restart the unit, press the power (enter) button.  

If the problem persists, please contact Salamander  

for technical advice.

Additional storage tanks can be connected to increase the 

stored volume of water. Note: total stored water should not 

exceed estimated usage for a 24 hour period.

A02

Current Overload

This code is displayed if the nominal pump current exceeds 

4.8A. 4 automatic reset attempts will be performed by the 

control unit before remaining off until manually reset. During 

these attempts, the current will be displayed. To restart the 

unit manually, press the power (enter) button. If the problem 

persists, please contact Salamander for technical advice.

A04

Fast Cycling 

(Hammering)

This code is displayed if the system loses pressure instantly 

when the outlets are closed this will force the pump to 

switch on and off in a fast cycle. The code is activated when 

3 consecutive cycles occur quickly. Check the air pre-charge 

pressure in the pressure vessel is 1.5 bar. To restart the 

unit, press the power (enter) button If the problem persists, 

please contact Salamander for technical advice.

A05

Pressure 

Transmitter 

Requires 

Recalibration

Contact Salamander for technical advice if this code is 

displayed.

Factory Reset (Control Unit)

Your unit is pre-set with its operating parameters during assembly and testing.

If your unit is failing to operate and if instructed to do so by the Salamander Tech Desk team,  

please follow these instructions to reset your unit:

Press and hold  

  + 

 +  

 

for 5 secs until the screen shows 

“nc”

Press     10 times until the screen shows 

“r50”

Press 

▲ 

to change the value to 

“r51”

Press    - the screen will show “OFF”

Press “A” for 3 seconds to set the max pump operating current  

- the number on screen will flash

Press 

▲ 

or 

▼ 

to display 

4.8

Press   - the screen will show “OFF”

Press 

▲ 

for 3 seconds to set the cut in pressure - the number on screen 

will flash

Press 

▲ 

or 

 to display 

2.0

Press   - the screen will show “OFF”

Press 

▼ 

for 3 seconds to set the cut out pressure - the number on screen 

will flash

Press 

▲ 

or 

 to display 

2.8

Press    the screen will show “OFF”

Press    to restart the unit.

Your unit is now reset and ready to resume normal operation.

ENTER

START

STOP

bar
psi
A

A

PRESS.

In normal operation the control unit 

displays pressure or current readings 

directly from the pump in the tank unit. 

An LED will be lit up to show whether 

the pressure is being displayed (in 

bar or psi) or whether current is being 

displayed (in Amps).

12    

13 

Summary of Contents for TankBoost Series

Page 1: ...nstallationandwarrantyguide forTankBoostrange Thisdocumentshouldbegiventotheenduserandretainedforfuturereference ShouldyouneedtocontactSalamanderPumpsyouwillneedthebelowinformation ISSUE 1 0 MARCH 202...

Page 2: ...them Incorrect fittingcouldcauseseriousinjury death propertydamageandinvalidatethewarranty Ifyourinstallationiscomplicatedoryouhave anyquestionspleaseconsultPUMPWISE TECHNICALHELPLINEon01915162002 018...

Page 3: ...creasethevolumeofstoredwater NOTE the additionalstoragetanksizemustmatchthe originalunitsizetoavoidanywaterimbalance Flow lpm Pressure bar 0 80 10 20 30 40 50 60 70 0 5 1 0 1 5 2 2 5 3 3 5 ProductDiag...

Page 4: ...bore isolating valve closed in normal operation Overflow to drain Combi Boiler Unvented Cylinder Mains Hot Water System Outlets TANK Overflow to drain Tank connection link Additional storage tanks mu...

Page 5: ...dstoremainbelow20 C The qualityofstoredwaterwilldeterioratewith timeandtemperature Bacterialgrowthrates willbehigherwhentheconditionsarewarm If thewaterremainsunusedforlongperiodsof time thetankshould...

Page 6: ...let Connections Checkthattheconnectionsareplumbedinthecorrectwayround andallvalvesareopenasperinstallationdiagram Checkthatanoutletisopentoallowwaterflow Insufficient storedwater Checkthatthemainsstop...

Page 7: ...ge pressureinthepressurevesselis1 5bar Torestartthe unit pressthepower enter buttonIftheproblempersists pleasecontactSalamanderfortechnicaladvice A05 Pressure Transmitter Requires Recalibration Contac...

Page 8: ...abletoyourspecific installation Theavoidanceofinstallationpitfalls Duetothetechnicalnatureofourproducts itisessentialthattheyarefittedaccording toourinstallationguidelines ThePumpWise teamareavailable...

Page 9: ...rrantyisregisteredwiththe Companywithin15daysofpurchase b ProductssuppliedbytheCompany butnotof theCompany smanufacture oneyearfrom dateofpurchase c Thewarrantyperiodinrespectofanyproduct repairedorre...

Page 10: ...18 19...

Page 11: ...c Colima Avenue Enterprise Park West Sunderland SR5 3XE For ROI EU Customers MT Agencies Ireland Ltd Fearn House Jamestown Business Park Jamestown Road Finglas Dublin 11 D11 K7TV Registeryourwarranty...

Reviews: