Salamander Pumps HomeBoost Installation Manual Download Page 4

3

Points applicable to 

whole house 

installation:

Points applicable to 

combi-boiler 

installation:

Do’s

   HomeBoost

 must be fitted to rigid fixed 

pipework preferably with vertical inlet  
and outlet

  Pipework above and below the pump must 

be securely fixed to the wall

  Only one HomeBoost

 may be fitted per 

household supply

  Ensure that installation complies with IET 

Wiring Regulations

  Allow 100mm on all sides for ventilation
  Ensure pump is protected from frost
  Complete all hot work fitting prior to 

HomeBoost

 installation

  We recommend that the pump is activated 

for at least five minutes every four weeks

  If the supply is known to be lime/calcium 

(hard) water, fit extra filtration before the 
pump

Do’s

  Install vertically or horizontally, mounted 

on cold water mains inlet to the house

  Locate the pump next to the mains  

stop tap

  Pump should be fitted before ANY other 

water outlets taken after the mains stop 
tap. If any outlets are between the stop tap 
and your HomeBoost

, they must be fitted 

with a non-return valve (NRV)

Do’s

   Install vertically or horizontally, mounted 

on cold water mains inlet to the combi 
boiler

  Locate the pump next to the combi-boiler 

OR on it’s cold water mains inlet

  Pump must exclusively feed the  

combi-boiler

Don’ts

   Never fit to hot water piping
  Never fit the pump to communal risers
  Never pump directly from or to another 

pump – only one HomeBoost

 may be 

installed per household supply

  Never fit to flexible pipework (e.g. tap 

connectors)

   HomeBoost

 cannot be used on outside 

coldwater storage tanks, bore holes or 
wells

  Never use jointing compounds,  

Boss White, hemp or steel wool

  Solder fluxes must not come into contact 

with the pump

  Never fit to restrictive or collapsed supply 

(eg lead main)

Pre-installation checklist

HomeBoost

 is suitable for two separate types of water boosting applications

1  Boosting the incoming mains water supply to a whole house 
2  Boosting the inlet mains water supply solely to a combination (combi) boiler.

Points applicable to 

either installation

 type:

x142741_SP_p4_vw.indd   4

07/01/2015   14:26

Summary of Contents for HomeBoost

Page 1: ...ISSUE 3 January 2015 Pump installation and warranty guide for HomeBoost Patented Product x142741_SP_p5_vw indd 1 09 01 2015 12 43...

Page 2: ...fitting will invalidate the warranty If your installation is complicated or you have any questions please consult the PumpWise Technical Helpline immediately 0191 516 2002 Additional help can also be...

Page 3: ...lication notes 4 5 Typical installations 6 Commissioning 7 General specifications 8 Lighting codes Trouble shooting 9 Fittings Kit 10 PumpWise and warranty 11 To the installer 12 Terms and conditions...

Page 4: ...ets are between the stop tap and your HomeBoost they must be fitted with a non return valve NRV Do s Install vertically or horizontally mounted on cold water mains inlet to the combi boiler Locate the...

Page 5: ...estricted incoming pipework and replacement water pipes should be installed in this scenario Installation must comply with the relevant requirements or local byelaws It is recommended that HomeBoost i...

Page 6: ...polymer pump body 6 Electrical requirements The HomeBoost must be connected to the electrical supply using the mains cable with the attached plug This plug must be connected to an accessible socket t...

Page 7: ...ll valve Tap connector Tap connector Isolating Ball valve Isolation valve for combi boiler Figure 4 Modified pipe work for clearance Mains stop tap Pipe centre to wall 37mm Figure 6 Earth continuity 4...

Page 8: ...t pump pipe work 2 Check that all isolating valves are open 3 Turn mains water on at the stop tap 4 Ensure all air is purged from the system 5 Check for natural flow on the cold outlets or hot outlets...

Page 9: ...ector x 22mm compression 2 off 22mm x 15mm compression reducer sets Initiation Fully automatic water flow operated requiring 3 litres per minute flow rate to initiate Temperature Maximum fluid tempera...

Page 10: ...ater supply only for several minutes Pump starts with all outlets closed Leak in system Check for leaks Outlet open Ensure all outlets are fully closed or capped i e no dead legs in pipe work Pump is...

Page 11: ...compression 2 x reducer 22mm x 15mm compression reducer Fitting Instructions WHOLE HOUSE COMBI ONLY WHOLE HOUSE COMBI ONLY Isolating ball valve Tap connector Isolating ball valve Tap connector Flat w...

Page 12: ...Our PumpWise commitment Our PumpWise helpline is here to help you and we aim to provide a support service second to none Installers and consumers can be sure of a speedy response to requests for tech...

Page 13: ...ty shall only be enforceable by you if the following terms and conditions have been complied with a That the pump has been installed in accordance with the installation instructions guidance and advic...

Page 14: ...13 Notes x142741_SP_p2_lh indd 14 16 12 2014 15 11...

Page 15: ...x142741_SP_p2_lh indd 15 16 12 2014 15 11...

Page 16: ...Salamander Pumped Shower Systems Limited Unit 2c Colima Avenue Sunderland SR5 3XE Tel 0191 516 2002 Fax 0191 548 4445 Email service salamanderpumps co uk x142741_SP_p2_lh indd 16 16 12 2014 15 11...

Reviews: