4
Product Description
Salamander pumps are suitable for pressure boosting vented stored water systems but please
note that inlet pressures to the pump and water temperatures must not exceed values stated
in the technical specifications.
Installation instructions
Please follow these installation instructions carefully. Failure to install your pump in
accordance with these instructions will invalidate your warranty. Any queries should be
directed to PumpWise on 0191 516 2002 (01844-3212 ROI).
Do not use Salamander pumps for applications other than those stated within the
pump description, or connect the pump directly to the cold mains.
To do so invalidates the warranty.
The plumbing installation must comply with “The Water Supply (Water Fittings)
Regulations 1999”, “BS 6700”, and building regulations.
Salamander pumps should be installed by a competent person and supervision in their use
should be given to children or anyone with impaired physical or mental capabilities
Please note that:
• CT FORCE 15 PT, 15 IPT, 20 PT, 20 PS, 20 IPS, 30 PT, 30 PS & 30 IPS, and CT Xtra 50, 50+,
54, 55, 55+, 59, 75, 75+, 79, 85, 85+, & 89 are shower specific pumps.
• CT FORCE 20 IPT & 30 IPT, CT Bathroom 60B, 80B, and CT Xtra 64H, 69H, 84H, & 94H are
whole house pumps
• CT FORCE 15 TU, 15 ITU, 20 TU, 20 ITU, 20 SU, 20 ISU, 30 TU, 30 ITU, 30 SU & 30 ISU,
CT Bathroom, 60BU, 80BU & 90BU, and CT Xtra 64 HU, 69HU, 84HU, & 94HU are
universal pumps.
• Inlets and outlets must be vertical and plumbed appropriately.
It is essential to ensure that: The cold stored water capacity is adequate for the entire
household requirements (eg minimum 136 litres (30 gal) for shower only, 227 litres (50 gal)
per bathroom, or 364 litres (80 gal) for one bathroom plus an en-suite shower room).
There is a maximum static head of 10 metres (100kPa/1.0Bar).
Cold supplies to the cylinder and the pump are taken from the opposite side of the cold
water storage cistern to the cold mains inlet. The bottom of the cold water storage cistern must
also be checked and cleared of debris (Figure 1).
In systems with more than two bathrooms,
the cold water supply to the cylinder must
be in 28mm pipework.
Multiple cold water storage cisterns must
be linked in accordance with the current
plumbing regulations with the bottom
of the cisterns level.
Never put a non-return valve, restricted
ballofix or an air vent on the supply pipework
to the pump
Outlet
to cylinder
Inlet
Bottom of cold cistern
must be cleared of debris
Outlet to pump
Figure 1: Tank inlet and outlet position