8
The fixed connection of the heating panel must contain an element allowing its disconnection from the power mains,
able to fully and completely disconnect contacts at all poles.
The power connection must be equipped with a device enabling disconnection from the power source, where the
distance of disconnected contacts is no less than 3.5 mm at all poles.
The power supply for the heating element is white.
The power supply for the light is black.
Colour coding of conductor wires:
•
Brown wire – L – phase
•
Blue wire – N – neutral
•
Yellow wire – PE - ground
The panel must not be placed in close proximity to an electrical outlet.
If the power connection cable is damaged,
the heating panel must be put out of operation.
Remove dust from the heating panel surface regularly by wiping with a damp cloth without any detergent or solving
agent, or possibly with a vacuum cleaner. Dust must always be removed prior to starting the heating season. The
heating panel must be cold and disconnected from the power source during maintenance.
During the first operation of the heating panel or the first operation in a given heating season, heat the panel
gradually and make sure the heated room is well aired.
Depending on the environment in the heated premises, the colour shade of the panel radiant surface may change.
All repairs must be carried out solely by the manufacturer.
The panel has a
10-year functional warranty
from the date of sale. The warranty does not apply to defects caused
by transport, inappropriate storage, unauthorized installation or any interference with the product structure. The
warranty also does not cover usual wear and tear of the panel or partial changes to the colour of the panel radiant
surface. The purchase receipt serves as the warranty certificate.
WARRANTY CONDITIONS
OPERATION AND MAINTENANCE
The installation, the power connection and the first operation of the appliance must be carried out by an individual
with the requisite qualifications. These heating panels are designed to be mounted onto ceilings at a height of
at
least 1.8 m above floor level
and at a distance of
at least 0.2 m from vertical structures
. There must be at least
0.5
m of unobstructed air space
below the heating panel measured from the vertical axes of the edges of the heating
panel to ensure free circulation of air and to prevent overheating of the unit. In bathrooms, the heating panel must
be installed in conformity with the regulation IEC 60364-7-701. Installation in the bathroom must ensure that the
person in the bath or the shower cannot touch the switch or other controlling devices.
PLACEMENT
ELECTRICAL INSTALLATION
L
N
PE
L
N
PE