544
Will not Vibrate
No, Are the Vibrate Switches in correct position?
No, See Next Page Or Ops Manual for More Info.
No, Does the machine Vibrate using continues Vibrate Switch on dash?
Does Machine Vibrate in one travel direction but not the other?
Yes, Open Circuit in harness to Lever Switch
No, Is there a Green Diagnostic Led on the ECO controller?
Yes, Short in harness to Lever Switch
No, Watch for Reb Blink Codes See TS Code List
Yes, Remove Motor and check to see if Shaft is broken?
ECO Controller
Yes, Repair broken shaft to Vibrate Motor.
ECO/Full
Speed
relay
ECO/Full
Speed
Fuse 20a
Yes, Repair Broken Shaft Parts
No, Inspect power across F16 20a. Is the fuse good?
Yes, Is there power at the Vibrate Mode Switch?
Red/Blue Stripe
No, Replace defective fuse or repair
connection.
No, Defective ECO/Full Speed relay or repair wire from
ECO/Full Speed Relay.
Yes, Is there power at the Vibrate
H/L Switch? Yellow Wire
No, Repair wiring from Mode Switch or Mode Switch
Yes, Is there power at Pin 9
High and Pin 10 Low of ECO
Controller?
Yes, Is there Power at the High/Low Vibrate Solenoids?
No, Repair wiring from Switch or Repair Switch.
No, Repair Wiring or ECO Controller
Yes, Test Valves Hydraulic Pump and Motors
ECO
Controller
Fuse 15a
Summary of Contents for 544
Page 1: ...544 Diagnostic Information...
Page 3: ...544...
Page 4: ...544 SV544 Operators Manual Scan QR Code to View...
Page 5: ...544...
Page 6: ...544...
Page 7: ...544...
Page 9: ...544...
Page 20: ...544...
Page 23: ...544...
Page 24: ...544 Battery Relay 30a Fuse SBF 65a and 75a 10a Fuse Main Starter Relay...
Page 25: ...544...
Page 26: ...544...
Page 27: ...544...
Page 28: ...544...
Page 29: ...544...
Page 31: ...544...