PDS23 Series
- 34 -
Function
Code
Function
Descriptions
Unit
Factory Setting
Modifica
tion Type
FA.18
Output current
when fault occurs
A
◎
FA.19
DC bus voltage
when fault occurs
V
◎
FD Group: Solar pumping special parameters
FD.0
4
Restart delay time
after stop at low
frequency
1
~
6000
min
2
〇
FD.07
Auto start when
power on
10
:
Disable
11
:
Enable
10
〇
FD.10
Water shortage
detection time
0
~
250 (0: disabled)
s
10
〇
FD.11
Lowest running
frequency when
yielding water
0.00
~
F0.10
Hz
20.00
〇
FD.12
Water shortage
detection current
ratio
corresponding to
no-load current
80.0
~
300.0
%
150.00
〇
FD.13
Interval of water
shortage detection
1
~
9000
min
20
〇
FD.14
Upper limit of
MPPT voltage
250-FD.15
430-FD.15
VDC
275/500
〇
FD.15
Lower limit of
MPPT voltage
FD.14-450
FD.14-800
VDC
350/600
〇
Parameter interpretation: