PACKAGE INCLUDES
1. Wall Touch Panel
2. Mounting Bracket
TOOLS AND MATERIALS REQUIRED
1. Drywall saw
2. #1 Phillips screwdriver (or drill with #1 Phillips bit)
3. Framing stud finder
SYSTEM REQUIREMENTS
The Wall Touch Panel communicates to the Symphony system
via Ethernet and receives power via Power over Ethernet (PoE).
1.
For commercial applications, use Ethernet cables, category
CAT5e or above.
2. For residential applications, use shielded Ethernet cables,
category CAT5e or above.
INSTALLATION
STEP 1: INSTALL MOUNTING BRACKET
1. Select a location on the wall to install the Wall Touch Panel. Using a
stud finder, ensure there is no framing behind the drywall in the
chosen location.
2. Using provided template, draw and cut 4.5” X 2.5” rectangular
opening in drywall for Mounting Bracket.
3. Attach clamp pad plates to the Mounting Bracket (if not already
attached) and set clamping distance to be slightly larger than
drywall thickness.
4. Turn clamp pads inwards and locate them inside Mounting Bracket
profile.
5. Slide Mounting Bracket into the opening and using the #1 Philips
screwdriver or drill, tighten screws to clamp the bracket to the
drywall.
STEP 2: RUN CABLES
Feed Ethernet cable through the Mounting Bracket opening into the
wall. Leave about two inches from Mounting Bracket front face to cable
end for easy connection.
Mounting Bracket
Touch Panel
FIGURE 1: PRODUCT VIEW
Clamping Pad
Mounting
Bracket
FIGURE 2: MOUNTING BRACKET INSTRUCTIONS