background image

PACKAGE INCLUDES

1.  Wall Touch Panel

2.  Mounting Bracket 

TOOLS AND MATERIALS REQUIRED

1.  Drywall saw
2.  #1 Phillips screwdriver (or drill with #1 Phillips bit)
3.  Framing stud finder 

SYSTEM REQUIREMENTS

The Wall Touch Panel communicates to the Symphony system  

via Ethernet and receives power via Power over Ethernet (PoE). 

1. 

For commercial applications, use Ethernet cables, category 

CAT5e or above.

2.  For residential applications, use shielded Ethernet cables, 

category CAT5e or above.

INSTALLATION

STEP 1: INSTALL MOUNTING BRACKET

1.  Select a location on the wall to install the Wall Touch Panel. Using a 

stud finder, ensure there is no framing behind the drywall in the 
chosen location.

2.  Using provided template, draw and cut 4.5” X 2.5” rectangular 

opening in drywall for Mounting Bracket.

3.  Attach clamp pad plates to the Mounting Bracket (if not already 

attached) and set clamping distance to be slightly larger than 

drywall thickness.

4.  Turn clamp pads inwards and locate them inside Mounting Bracket 

profile. 

5.  Slide Mounting Bracket into the opening and using the #1 Philips 

screwdriver or drill, tighten screws to clamp the bracket to the 
drywall.

STEP 2: RUN CABLES

Feed Ethernet cable through the Mounting Bracket opening into the 

wall. Leave about two inches from Mounting Bracket front face to cable 

end for easy connection.   

Mounting Bracket

Touch Panel

FIGURE 1: PRODUCT VIEW

Clamping Pad

Mounting 

Bracket

FIGURE 2: MOUNTING BRACKET INSTRUCTIONS

sageglass.com/resources