II. General Safety Information

II

I. Functions

IX. Firmware Upgrading

 

X. Getting Familiar with Device

XI. Measurement Instructions

I. Product Overview

Contents

V. Operational Environment

VI. General Inspections

 

VII. Functional Inspections

VIII. Battery Charging Instructions

P1

P1

P2

P3

P3

P4

P4

P5

P5

P4

XII.  Certification Marks

P7

IV. Parameters

P14

Summary of Contents for MiniDSO DS211

Page 1: ...D S 2 11 U s e r M a n u a l V1 07...

Page 2: ...etting Familiar with Device XI Measurement Instructions I Product Overview Contents V Operational Environment VI General Inspections VII Functional Inspections VIII Battery Charging Instructions P1 P1...

Page 3: ...oid fire or personal injury Read carefully all the following safety precautions to Use proper power cord Please use power cord specified for this product and certified for use of your country region C...

Page 4: ...log input impedance 500K Maximum input voltage 40Vpp x1probe Coupling AC DC Synchronous mode Auto Normal Single Scan Auto measurement Inbuilt signal Generator 10Hz 1MHz 1 2 5sequence step Storage 8MB...

Page 5: ...Recharging Via micro USB Cable Size 106mm 55 5mm 11mm Battery 500mAH Weight 66g IV Parameters V Operational Environment Humidity HighTemperature 50 C 0 60 RH 40 C LowTemperature 0 C 40 C 10 90 RH Hig...

Page 6: ...t and then plug in 4 VIII Battery Charging Instructions When the battery voltage status turns to or display brightness is relatively dim please charge the battery in time charging is workable in both...

Page 7: ...Power to enter into DFU firmware upgrading mode 3 Use USB data cord to connect DS211 to your PC and a removable hard disk named DFU V3_60_D will appear on your PC copy the hex firmware to the root di...

Page 8: ...f each button Note that each item s color in Parameter Area is the same as that in Measurement Area Run pause button Save parameter Slide Up Slide Down Set parameter Reduce Slide Left On Off Sub menu...

Page 9: ...Inp D D Inp Inp D F Trigmode Rising falling edge G Trigger accuracy 40mV 3 9V H Automatic Normal Single Scan AUTO NORM SINGL SCAN A Battery supply USB charging I V 10 0V T 1 6mS Sub item parameters Ve...

Page 10: ...ting See P12 Waveform output parameter setting See P13 System function setting See P13 Note After all the changes to setting are finished long press to save the changes in accordance with prompts 3 Sp...

Page 11: ...check waveform 1k 8k storage depth Time measurement cursorT1 Time measurement cursorT2 Show hide measurement cursor Y Ranges Coupling ProbeAtt Y Offset CursorV1 CursorV2 Hide_Vn Ordinate unit amplitud...

Page 12: ...on F will appear when open doublr click Button M to auto fit Horizontal Triggering Position Level Horizontal Triggering accuracy Display Hide Horizontal Triggering Position Level 4 Me Parameter Notes...

Page 13: ...alculation Hide the two waveform computation line purple line 11 Position the cursor on EX option press M to pop up window select Ext Hide option and change the parameter value at the blinking cursor...

Page 14: ...oad Buf Save bmp file waveform figure into flash disk Save dat file into flash disk Save buf file sampling buffer data into flash disk Save csv file export sampling buffer data into flash disk Save sv...

Page 15: ...ore Data Press to auto calibration save setting per prompt Adjust standby time Press or to choose a standby time of 0 60 mins Adjust power off time Press or to choose a power off timeof 0 60 mins When...

Page 16: ...ies with all the relevant European Legal Directives Do not dispose in domestice household waste This device complies with the WEEE Directive 2002 96 EC marking requirement This affixed product label i...