SAH WSK Series User Manual Download Page 5

WSK INTELLIGENT TERE AND HUMIDITY CONTROLLER

WSK INTELLIGENT TERE AND HUMIDITY CONTROLLER

WSK INTELLIGENT TERE AND HUMIDITY CONTROLLER

WSK INTELLIGENT TERE AND HUMIDITY CONTROLLER

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER

Panel Explaination and Each Function

Panel show

Content description

Temp Measuring

Display value model

Mode content parameter values

Humidity Measuring

 Temperature control output indicator light

Humidity control output indicator light

Temperature process alarm indicator lights

Humidity process alarm indicator lights

Temperature disconnection alarm indicator lights

Humidity disconnection alarm indicator lights

The communications light

Instrument power light work

Increasing Key

Decreasing

 

Key

Up Key

Down Key

Displacement Key

Mode Key

Confirm Key

Quit Key

Operation

 

Process

Boot Up Process

Open the Power

Self-checking of LED device

Automatic

Automatic

Transfomation

)

Transfomation

)

Displaying the current temperature and humidity

All LEDS light up

Measuring the current 
temperature and humidity 

Set the mode and modify the parameter

In normal display mode of 

℃/%R

H

press the “SET” button to enter the 

temperature and humidity controlling and alarming settings. Press the “SET” 
button for more than 3 seconds to enter the setting mode condition.

Shift Key for more than 3 seconds

SET

“SET”Shift Key

To press “SET” shift key again to  enter the condition of modifying the content and parameter

To modify the parameter content

Confirm Key to save the changes 

Confirm Key to return

 

Displaying current temperature 
       and humidity

 

Summary of Contents for WSK Series

Page 1: ...WSK INTELLIGENT TEMPERATUREAND HUMIDITY CONTROLLER USER MANUAL ...

Page 2: ...n to prevent the power cord and input output strong current shock 2 Power supply In order to prevent the equipment damage or failure please use the rated power To prevent electric shock or equipment failure all wiring complete rear can supply 3 Prohibited to use in the vicinity of flammable gas As fire explosion or equipment damage banned in flammable explosive gas venting occasion use 4 It is for...

Page 3: ...er supply 85V 265V 50 60Hz AC Transformer 110V 220V 380V 50 60Hz DC 24V 36V 48V 110V 220V Accuracy class Temperature 0 5 C Humidity 5 RH Resolving power 14 Bit Cycle of sampling 0 5 Sec Measurement range Temperature 40 100 C Humidity 0 100 RH Display Measured values and set values by LED Output condition and alarming condition by LED lights Way of operating Controlling by two step settable turn di...

Page 4: ... TEMPERATU RE AND HUMIDITY CONTROLLER WSK INTELLIGENT TEMPERATU RE AND HUMIDITY CONTROLLER WSK INTELLIGENT TEMPERATU RE AND HUMIDITY CONTROLLER WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER The wiring diagram subject to the product itself the wiring diagram 485 Frame Size Hole Size Frame Size and Hole Size Frame Size and Installation Hole S...

Page 5: ...indicator lights The communications light Instrument power light work Increasing Key Decreasing Key Up Key Down Key Displacement Key Mode Key Confirm Key Quit Key Operation Process Boot Up Process Open the Power Self checking of LED device Automatic Automatic Transfomation Transfomation Displaying the current temperature and humidity All LEDS light up Measuring the current temperature and humidity...

Page 6: ...s the master slave communication response mode connections on a communication line First of all the main computer of the signal only address addressing to a terminal equipment machine and then the response signal from the terminal to transmit to host in the opposite direction i e in a single communication line signal transmission instead of two direction all communication data flow half duplex wor...

Page 7: ...he address of the query When the terminal sends back a response in the response from the machine address data and tell the host which terminal is to communicate with them ONE ONE ONE ONE TWO TWO CODE Meaning Behavior Function Code Table 2 Tell what is addressing to the terminal to perform the function Listed in the following table shows the supported code function and their meaning and function Ta...

Page 8: ...ng setting Temperature heater disconnection alarming setting Temperature process alarming setting Humidity process alarming setting Humidity process alarming state Temperature process alarming state ON ON ON ON OFF OFF OFF OFF OFF Lower deviation alarming Lower deviation alarming Higher deviation alarming Higher deviation alarming 3 is the highest brightness the lED display brightness the controll...

Reviews: