The spray gun, hoses and the rest of the unit must be cleaned 

with the appropriate thinner, in order to remove any remaining 

product after each use. The useful service life of the unit 

depends largely on the effectiveness of the cleaning process.
The unit must be cleaned:
- Before using it for the first time, in order to eliminate the 

traces of maintenance oil that the equipment comes with 

from the factory. 

- After each use.

- When proceeding to apply a different product (different 

colour or characteristics) to what we are currently using.

Before proceeding to clean the unit you must have followed 

each and every one of the steps described in the section 

Stopping when work is finished (Section 12.2)

. This 

implies that the unit and its accessories must be 

depressurised and without any product inside.

Always use an appropriate thinner when cleaning the unit. 

Always use water for waterborne products, for other products 

always use whatever is recommended by the manufacturer 

of the product to be applied.

1.- Add the thinner to the external container where 

the suction probe (No. 1) is located, by inserting in 

both cases the product return hose (No. 2).

2.- Connect the unit to the compressed air network 

(No. 9)

3.- When the solvent starts to flow through the 

product return hose (No. 2) close the return key 

(No. 3).

4.- Turn the pressure regulator control (No. 4) to 

adjust the working pressure. 

13. CLEANING

-  19  -

11. OPERATION

VERY IMPORTANT!!

Only if the whole process indicated in the section regarding DEPRESSURISATION, described in section 10, 

has been correctly carried out will the unit be ready to be started and used again.

The incorrect observance of this Depressurisation process could lead to malfunctions in the equipment and 

deterioration of its components.

Check and fill every day with the lubricant OILPACK (30090098), if necessary, the existing accommodation in 

the gland (No. 34). Replace if dirty or damage.

1.- Insert the suction probe (No. 1) in the container with the 

product to be applied.
2.- Turn the pressure regulator (No. 4) clockwise, until you 

see that the product circulates through the unit and flows 

through the return hose (No. 2).
Insert the product return hose (No. 2) in the actual product.
3.- Close the product return key (Nº 3).

 

4.- Turn the product regulator control (No. 4) to adjust the 

required pressure to be applied, visible on the pressure 

gauge (No. 7).
5.- Carry out an uncompromising application test by directing 

the application on an earthed metallic container, WITHOUT 

the air cap on the gun .
6.- Pull the trigger of the spray gun while maintaining part 

of the same (for example the hand guard), in contact with 

the container being sprayed.
In a few seconds the product will start to flow from the head 

of the gun without the air cap. Keep the product flowing until 

it there is a continuous flow (no air) through the head. 
7.- Activate the gun's safety latch.
8.- Assemble the air cap on the gun.

9.- Adjust the Spray Pressure:

9.1 Adjust the spray pressure by turning the pressure 

regulator control (No. 5) until the product flowing from 

the gun is completely atomised.

To avoid spraying an excessive amount of product that 

causes excessive misting, and produces premature wear 

of the air cap and the components of the unit, always 

use the lowest possible pressure to obtain the 

performance and micronage expressed by the product 

manufacturer (greater spray pressure does not mean a 

better finish, while it does mean worse performance and 

product transfer).  

9.2 Once the pressure at which the product atomises is 

determined, if a greater amount of product needs to be 

applied, we recommend that, preferably, a larger air cap 

is used instead of increasing the pressure.

9.3 To achieve the desired spray pattern, activate the 

gun's safety latch, loosen the screw that fixes the air 

cap and move it to the desired position.

9.4.-Tighten the air cap holder screw again.

During application, the amount of product applied to 

areas with difficult access, reduced space, etc. can be 

reduced by decreasing the travel distance of the trigger 

when loosening the grip of your fingers on it.

Adjust the distance between the air cap and the object to 

be sprayed (10 / 20 cm.) depending on the same, the product 

to be applied and the working conditions, in order to increase 

transfer and obtain a reduction in the amount of mist 

depending on the air cap used in each case.

12. STOPPING

1.- Short stop

When stopping for a short period of time that does not pose 

possible problems with catalysation or hardening of the 

product inside the unit and accessories, keep the product 

suction probe submerged in the product and apply the 

procedure of Depressurisation (Section 10).

Disassemble the air cap and dip it in thinner.
2.- Stopping when work is finished

2.1.- Turn the pressure regulator control. (No. 4) 

anticlockwise all the way (Minimum).

2.2.- Pull the spray gun trigger, holding it until no more 

product comes out of the gun.

2.3.- Lock the spray gun trigger with the safety latch.

2.4.- Open the product return key (No. 3) to then be 

able to recover the product remaining inside the unit.

2.5.- Turn the pressure regulator (No. 4) clockwise 

until the product flows out of the product return probe 

(No. 2), thus returning the existing product inside the 

unit to its container.

The unit is now ready to be immediately cleaned.

Summary of Contents for RAIDER 300

Page 1: ...i n s t r u c t i o n m a n u a l s p a r e p a r t s l i s t raider...

Page 2: ......

Page 3: ...ge 18 8 Service Kits page 18 9 Start up page 18 10 Depressurisation page 18 11 Operation page 19 12 Stopping page 19 12 1 Short stop page 19 12 2 Stopping when work is finished page 19 13 Cleaning pag...

Page 4: ...sonnel instructed in its use and must be employed only for the purpose for which it was designed Likewise accident prevention standards work centre regulations and directives and current legislation a...

Page 5: ...ly verify one a week its electrical continuity If its resistance exceeds the recommended limits it must be fixed An equipment unit without or with a faulty grounding connec tion may make the installat...

Page 6: ...he Technical Service of SAGOLA S A 6 USEFUL TIPS The Raider 300 equipment can be used to apply conveniently diluted products used widely in the Construction Automotive Timber Plastics Industry etc The...

Page 7: ...maintaining part of the same for example the hand guard in contact with the container being sprayed In a few seconds the product will start to flow from the head of the gun without the air cap Keep t...

Page 8: ...The gun can be cleaned with thinners or detergents in a gun washing machine If you opt for this cleaning system we advise you to remember the following considerations which if not applied may damage t...

Page 9: ...lation and regulations Near the unit only keep the amount of product and thinner required for the work being done at that time After work has been completed thinners and the product to be applied must...

Page 10: ...damaged The suction Probe is damaged The Gun has no Aircap The anti pulsation Filter is blocked The aircap is worn The product is too thick The product is too thick The pump Pressure is low The produc...

Page 11: ...low Clean it and or Replace it Replace it Do not exceed the maximum recommended work pressures Send the unit to the S A T SAGOLA Replace the gaskets and or the Piston Shaft Check that the air inlet pr...

Reviews: