20
5.2 – MASTER/SLAVE MODE
In this mode, more units can be linked together as a single chain and work in a synchronized
way.
•
Link together all the units from the connector DMX OUT to DMX IN.
•
Define the first unit of the chain as MASTER, all other units must be set in SLAVE mode.
•
Operate the Master unit in Automatic mode or Static mode to operate the entire system.
The entire chain of Slave unit will act as the Master unit
5.3 - DMX MODE
6 CH 10CH 11CH 16CH
48CH
96CH
Value
Function
1
1
1
1
1
1
000
–
255
Red
(sector 1 in 48 and 96CH mode)
2
000
–
255
Red Fine
(sector 1 in 96CH mode)
2
2
2
2
2
3
000
–
255
Green
(sector 1 in 48 and 96CH mode)
4
000
–
255
Green Fine
(sector 1 in 96CH mode)
3
3
3
3
3
5
000
–
255
Blue
(sector 1 in 48 and 96CH mode)
6
000
–
255
Blue Fine
(sector 1 in 96CH mode)
4
4
4
4
4
7
000
–
255
White
(sector 1 in 48 and 96CH mode)
8
000
–
255
White Fine
(sector 1 in 96CH mode)
5
5
5
5
5
9
000
–
255
Amber
(sector 1 in 48 and 96CH mode)
10
000
–
255
Amber Fine
(sector 1 in 96CH mode)
6
6
6
6
6
11
000
–
255
UV
(sector 1 in 48 and 96CH mode)
12
000
–
255
UV Fine
(sector 1 in 96CH mode)
…48ch
…96ch
7
7
000
–
031
032
–
063
064
–
095
096
–
127
128
–
159
160
–
191
192
–
223
224
–
255
Strobe:
LED ON
LED OFF
Strobe effect slow to fast
LED ON
Pulse-effect in sequence
LED ON
Random strobe effect slow to fast
LED ON
7
8
8
000
–
255
Master Dimmer 8bit
8
9
9
000
–
255
Master Dimmer 16bit
10
000
–
255
Color Macro
11
6
000
–
010
011
–
026
027
–
043
044
–
060
061
–
076
077
–
093
094
–
110
111
–
126
127
–
143
Auto programs:
No function
DREAM
METEOR
FADE
CHANG
Flow1
Flow2
Flow3
Flow4