background image

 
 
 

 
 

21 

5. - SETUP

 

 
 

5.1 – MENU

 

 

MENU 

SUBMENU 1 

SUBMENU 2 

DESCRIPTION 

ADDRESS 

001 

 512 

 

Set the DMX address 

CONTROL 

MODE 

3

CHANNEL 

 

Set channel mode with 3 channels 

4

CHANNEL 

 

Set channel mode with 4 channels 

6

CHANNEL 

 

Set channel mode with 6 channels 

10

CHANNEL 

 

Set channel mode with 10 channels 

PERSONALITY 

DIMMER 

CURVE 

LINEAR 

Linear dimming curve 

SQUARE LAW  Square law dimming curve 
INV SQUARE 

Inverse square law dimming curve 

S-CURVE 

S-curve dimming curve 

FANS MODE 

AUTO 

Auto fans mode 

FAST 

Fast speed fans mode 

NORMAL 

Normal speed fans mode 

SILENT 

Silent fans mode 

DMX RESET 

CANCEL 

Return to menu 

OK 

Reset DMX settings 

DISPLAY 

ALWAYS 

Screen keep on always 

2 MINUTES 

Screen off after 2 minutes 

5 MINUTES 

Screen off after 5 minutes 

10 MINUTES 

Screen off after 10 minutes 

ROTATION 

NORMAL 

Display on normal direction 

180° 

Display rotated 180° 

DMX ERROR 

SAVE 

If DMX lose, then keep last state 

BLACK 

If DMX lose, then clear all buffer 

MASTER 

CONTR 

ON 

Setting master mode ON 

OFF 

Setting master mode OFF 

PASS CODE 

ON 

No pass code mode when in screen 
protect 

OFF 

Enable pass code mode when in screen 
protect 

FIXTURE ID 

VALUE xxxx 

Setting ID number 

SETTING 

DEFAULT 

QUIT 

 

LOAD 

Return all setting to factory default 

CUSTOM 1 

LOAD 

Load custom 1 setting from memory 

SAVE 

Save current fixture settings as custom 
1 and overwrite existing custom 1 data 

CUSTOM 2 

LOAD 

Load custom 2 setting from memory 

SAVE 

Save current fixture settings as custom 
2 and overwrite existing custom 2 data 

Summary of Contents for BLAZER 1500S

Page 1: ...BLAZER 1500S LED STROBE 1500W Order code SG BLAZER1500S MANUALE UTENTE USER MANUAL...

Page 2: ...INSTALLAZIONE ED ACCENSIONE p 7 5 ISTRUZIONI PER L USO p 9 6 MANUTENZIONE p 14 7 SPECIFICHE TECNICHE p 14 INDEX 1 INTRODUCTION p 15 2 SAFETY INSTRUCTIONS p 16 3 OPENING AND CONTROL p 18 4 INSTALLATIO...

Page 3: ...te a separare questo prodotto da altri tipi di rifiuti e di riciclarlo in maniera responsabile per favorire il riutilizzo sostenibile delle risorse materiali Gli utenti domestici sono invitati a conta...

Page 4: ...o di ancoraggio sia stabile prima di posizionare il prodotto Il cavo di sicurezza deve essere debitamente agganciato al dispositivo e fissato alla struttura di sostegno in modo che in caso di cediment...

Page 5: ...anche la potenza assorbita a cui necessario fare riferimento per valutare il numero massimo di dispositivi da collegare alla linea elettrica al fine di evitare sovraccarichi Se il cavo di alimentazio...

Page 6: ...verifica ATTENZIONE Se l apparecchio stato esposto a drastici sbalzi di temperatura lasciare spenta l unit finch non raggiunge la temperatura ambiente in quanto la presenza di condensa potrebbe danne...

Page 7: ...o fissaggio dell unit L unit pu essere installata a pavimento a soffitto o su truss ATTENZIONE E OBBLIGATORIO il montaggio della fune di sicurezza PLH232 PLH248 venduta separatamente nel caso in cui...

Page 8: ...ttato come indicato nella targhetta dei dati elettrici 4 3 COLLEGAMENTO ALLA CATENA DMX Utilizzare un cavo conforme alle specifiche EIA RS 485 bipolare intrecciato schermato 120Ohm di impedenza caratt...

Page 9: ...so 2 MINUTES Display spento dopo 2 minuti 5 MINUTES Display spento dopo 5 minuti 10 MINUTES Display spento dopo 10 minuti ROTATION NORMAL Display direzione normale 180 Display ruotato di 180 DMX ERROR...

Page 10: ...Temperatura interna RDM UID xxxxxxxxxxxxx RDM ID ERROR LIST xxxxxxxxxxx Lista errori FIXTURE TIME Hours xxxx Minutes xxxx Totale ore lavorate dalla macchina 5 2 MODALITA MASTER SLAVE In questa modalit...

Page 11: ...Velocit Strobo Modalit 4 canali Canali Valori Descrizione 1 000 255 Intensit Beam 2 000 255 Durata Strobo 3 000 255 Velocit Strobo 4 000 005 Nessun effetto 006 042 Rampa up beam 043 085 Rampa down be...

Page 12: ...ear 1 sec 016 023 Curva Square law 1 sec 024 031 Inverso Square law dimmer 1 sec 032 039 Curva dimmer S curve 1 sec 040 047 Nessuna funzione 048 055 Modalit ventola Auto 056 063 Modalit ventola Veloce...

Page 13: ...07 Nessuna funzione 008 015 Curva Linear 1 sec 016 023 Curva Square law 1 sec 024 031 Inverso square law dimmer 1 sec 032 039 Curva dimmer S curve 1 sec 040 047 Nessuna funzione 048 055 Modalit ventol...

Page 14: ...zzola morbida o un panno per lenti per rimuovere la polvere depositata Le lenti come qualsiasi altra parte eventualmente danneggiata devono essere sostituite con ricambi originali 7 SPECIFICHE TECNICH...

Page 15: ...to the environment the user is encouraged to separate this product from other kinds of wastes and recycle it responsibly to promote the sustainable reuse of material resources Home users are encourage...

Page 16: ...point is stable before positioning the product The safety cable must be properly attached to the device and fixed to the supporting structure so that in case of failure of the primary supporting syst...

Page 17: ...mption that is necessary to refer to evaluate the maximum number of devices to be connected to the electricity line in order to avoid power overloading If the external power cord of this light is dama...

Page 18: ...verification WARNING If the product has been exposed to drastic temperature changes let the unit turned off until it reaches room temperature because the presence of condensation can damage the produ...

Page 19: ...ation or unit fixing The unit can be installed on the floor on the ceiling or on a truss c WARNING IT S REQUIRED the mounting of the safety rope PLH232 PLH248 sold separately in the case where the pro...

Page 20: ...the electrical data label 4 3 CONNECTION TO THE DMX CHAIN Use a cable conforming to specifications EIA RS 485 pole twisted shielded 120Ohm characteristic impedance and low capacity SAGITTER SG DMX3 S...

Page 21: ...een keep on always 2 MINUTES Screen off after 2 minutes 5 MINUTES Screen off after 5 minutes 10 MINUTES Screen off after 10 minutes ROTATION NORMAL Display on normal direction 180 Display rotated 180...

Page 22: ...x Software version TEMPERATURE T xx C RDM UID xxxxxxxxxxxxx ERROR LIST xxxxxxxxxxx FIXTURE TIME Hours xxxx Minutes xxxx Display total hours of operation of the projector 5 2 MASTER SLAVE MODE In this...

Page 23: ...3 000 255 Strobe speed 4 channels mode Channel Values Description 1 000 255 Beam Intensity 2 000 255 Strobe duration 3 000 255 Strobe speed 4 000 005 No effect beam 006 042 Ramp up beam 043 085 Ramp...

Page 24: ...ion 008 015 Linear Dimming curve 1 sec 016 023 Square law Dimming curve 1 sec 024 031 Inverse square law Dimming 1 sec 032 039 S curve Dimming curve 1 sec 040 047 No function 048 055 Auto Fans mode 05...

Page 25: ...s flash over low high 9 000 007 No function 008 015 Linear Dimming curve 1 sec 016 023 Square law Dimming curve 1 sec 024 031 Inverse square law Dimming 1 sec 032 039 S curve Dimming curve 1 sec 040 0...

Page 26: ...ompressor and a soft brush or a lens cloth to remove the dust deposited The lenses like any other damaged part must be replaced with original spare parts 7 TECHNICAL SPECIFICATIONS Power Supply 100 24...

Page 27: ...27...

Page 28: ...28...

Reviews: