Use this signal to wait a controller “ACK” or to drive the terminal led.
LED IN signal
/cfg/Maccess/Wiegand/dataclock/
Led IN
0 (default)
Active
The led in signal is ignored.
1 Inactive
The MorphoAccessTM led is driven by the
led in
signal:
•
led in
= 0
led is green
•
led in
= 1
led is off
2
The Wiegand in port is used as a dual led in port.
D1 is connected to Led in green and D0 to Led in red.
This feature improves integration in an access control system
(ACS). Result of biometric matching is validated by the ACS
through Led in signals.
When the ACS validates the control a timeout must be specified.
ACK timeout
/cfg/Maccess/Wiegand/dataclock/
Timeout
Time in seconds during which the
MorphoAccess™ will wait for an
acknowledgement signal from the ACS
through Led in signals.
(“Led IN 2“ mode).
SK-0000011145-05
SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
79
Summary of Contents for MORPHOACCESS 200
Page 1: ...SAGEM D fense S curit MORPHOACCESS TM Installation Guide MorphoAccessTM 200 220 300 July 2006...
Page 2: ...2 SAGEM D fense S curit document Reproduction and disclosure forbidden SK 0000011145 05...
Page 8: ...8 SAGEM D fense S curit document Reproduction and disclosure forbidden SK 0000011145 05...
Page 117: ...SK 0000011145 05 SAGEM D fense S curit document Reproduction and disclosure forbidden 117...