Environment

 

the modem should be installed and used inside a building.

 

the room temperature should not exceed 45ºC.

 

The modem can be placed on a desktop or fixed vertically in its wall mounting.

 

the modem should not be exposed to strong sunlight or placed near a substantial 

source of heat.

 

the modem should not be placed in an environment where it would be subjected to 

considerable steam condensation.

 

the modem should not be exposed to splashes of water.

 

the modem’s casing should not be covered.

 

the modem and its peripherals should not be used for outdoor transmissions.

power supply source

 

the modem’s mains adapter should not be covered.

 

the modem comes with its own mains adapter. it should not be used with another 

adapter.

 

this class ii adapter does not need to be grounded (earthed). the connection to the 

electrical network should comply with the indications given on the label.

 

use a readily accessible mains outlet located near the modem. the power supply cord 

is 2 m long.

 

arrange the power supply cord in such a way as to avoid any accidental power cut to 

the modem.

 

the modem is designed to be connected to a gg- (ground-to-ground) or gn- (ground-

to-neutral) type power supply network.

 

the modem is not designed to be connected to an electrical installation with it type 

diagram (neutral connected to earth through an impedance).

 

protection against short-circuits and leaks between phase, neutral and earth should be 

provided by the building’s electrical installation. the power supply circuit for this 

equipment  should be fitted with 16 A overcurrent protection and differential protection.

 

the modem should be connected to the mains via a readily accessible wall socket 

ensuring the electric cutting.

Maintenance

 

It is prohibited to open the casing. This must be done only by qualified personnel appro

-

ved by your supplier.

 

do not use liquid or aerosol cleaning agents.

253156400-A_GIR 1201 V2 STD-gb.i15   15

14/10/2008   17:00:08

Summary of Contents for 1201

Page 1: ...SAGEM F stTM 1201 1241 V2 Quick Installation Guide 253156400 A_GIR 1201 V2 STD gb i1 1 14 10 2008 16 59 35...

Page 2: ...e CD rom 4 3 1 Installation on the ethernet port 6 3 2 Installation on the USB port 7 3 3 reinstalling or uninstalling your modem 8 4 troubleshooting 9 4 1 status of the leds on the front 9 4 2 MODEM...

Page 3: ...GEM F stTM 1241 V2 equipment include an Ethernet interface ETH and an USB interface SAGEM F stTM 1201 V2 and SAGEM F stTM 1241 V2 products can be provided in Bridged or Routed version according to the...

Page 4: ...ts of the pack Before you start the installation make sure that the pack contains the following items Contents of the pack Note The modem can be either in white or black colour 253156400 A_GIR 1201 V2...

Page 5: ...G YOUR MODEM Connection Follow the procedure according to the stages described in the CD ROM installation and connect your telephone in accordance with the drawing below 2 2 Connecting additional tele...

Page 6: ...escribed below was undertaken in Windows VistaTM Installation in other Windows 98 ME 2000 and XP can be slightly different insert the CD ROM into the relevant drive the screen oppo site will appear cl...

Page 7: ...V2 The screen opposite will appear Select the mode of connection that you wish Ethernet or USB to connect your modem to your computer Installation from the CD ROM 253156400 A_GIR 1201 V2 STD gb i7 7...

Page 8: ...appear You must enter your username then your connection password This information is provided by your Internet Service Provider ISP Once you have entered the configuration parameters a window will a...

Page 9: ...ar You must enter your user name then your connection password This information is provided by your Internet Service Provider ISP 3 2 Installation on the USB port Once you have entered the configurati...

Page 10: ...modem insert again your CD ROM in the relevant drive the following screen will appear Installation from the CD ROM Click on You want to configure your modem or You want to uninstall your modem accordi...

Page 11: ...On steady Power present Synchronised ADSL line Public address available Active Ethernet link Active USB link Blinking Failure detected at the time of starting X At WAN traffic rate At LAN traffic rat...

Page 12: ...o VC Virtual Channel Router rebooting Modem is rebooting Red Access denied Erroneous Login and or password This is displayed permanently in a box at the top right of each window in the HTTP configu ra...

Page 13: ...supervision section select the Status heading then the Diagnostics menu in the relevant list located in the left of each window the following screen woll appear Buttons Update the data displayed on th...

Page 14: ...ving trouble connecting to the Internet we recommend that you restart your modem or possibly return to the factory configuration using the procedures described below Restarting your modem To restart y...

Page 15: ...should comply with the indications given on the label Use a readily accessible mains outlet located near the modem The power supply cord is 2 m long Arrange the power supply cord in such a way as to a...

Page 16: ...with EMC regulations as well as the Low Voltage Directive published by the Commission of the European Community CEC EC Declaration EC compliance declaration Sagem Communications declares that the pro...

Page 17: ..._______________ _________________________________________________________________ ___________________________________________________________ __________________________________________________________...

Page 18: ..._____ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ______________...

Page 19: ...om 253 156 400 ed A 3 000 323 061 R11 000 01 Si ge social 27 rue Leblanc 75015 Paris France T l 33 1 58 11 77 00 Fax 33 1 58 11 77 77 http www sagem communications com Soci t Anonyme au capital de 158...

Reviews: