Sensor configuration can be configured in 02 methods:

Method 1: Configuring via Downlink message. Please find the instructions in sections D and E in 

this link

, but

please take note of the 

FW version of the Document.

Method 2: Configuring via 

offline cable

.

Some parameters are read-only, and some are read and writeable.

To read the parameters, use the off-line cable as per the above instruction.

Via uplink message, users can read only one parameter, which is the CURRENT_CONFIGURATION.

The below tables are the lists of the parameters of the device.

Read-only Parameter Table

Modbus

Register

(Decimal)

Modbus

Register

(Hex)

Function

Code (Read)

No. of

Registers

Description

Range

Format

Property

Comment

2

2

3

4

FW_VERSION

 

string

Read

 

6

6

3

2

HW_VERSION

 

string

Read

 

8

8

3

2

DEVICE_ID

 

hex

Read

Product ID

10

A

3

4

DEVICE_PAC

 

hex

Read

Product PAC

14

E

3

1

SENSOR_TYPE

1-255

uint16

Read

Sensor or
Input Type

Read/Write Parameter Table

Modbus

Register

(Decimal)

Modbus

Register

(Hex)

Function

Code

(Read)

Function

Code

(Write)

No. of

Registers

Description

Range

Default

Format

Property

Comment

270

10E

3

16

4

CURRENT_CONFIGURATION

 

 

hex

Read/Write

Check
sections D
& E in this

Payload Document

274

112

3

16

1

SERVER_CONFIG  

0

uint16

Read/Write

0: Send to
Sigfox
Network
1: Send to
Dongle

276

114

3

16

1

RADIO_CONFIG

1-4

4

uint16

Read/Write

RC zones
selection
1, 2 , 3, 4
is RC1,
RC2,
RC3s, RC4

277

115

3

16

1

TX_POWER

 

20

int16

Read/Write

RF Tx
power

Note: THE SENSOR IS ONLY ACTIVE FOR OFFLINE CONFIGURATION IN THE FIRST 60 SINCE POWER UP

BY BATTERY OR PLUGGING THE CONFIGURATION CABLE.

3.2.2 What parameters of the device are configured?

Summary of Contents for WSSFCEX-GHC

Page 1: ...gfox Product Type 1 part Mounting Type Wall mount Powered by 1 x C battery LiSOCl2 recommend SAFT LS26500 Information Changes in this version v s the previous version Item Changes Changed by Changed D...

Page 2: ...the device Case 5 During the commissioning testing or calibration sensor the user can force the device to send the uplink message to get the data immediately This message is called FORCE_DATA The pay...

Page 3: ...late Device PAC Get Devive PAC on the device nameplate 1 2 What s in the package The package includes the following items 01 x Main device 01 x Magnet key 01 x Antenna Type N connector 1 3 Quick Test...

Page 4: ...batteries into the device in Safe Zone Step 2 Add the device to Sigfox Backend Step 3 Install the batteries to the device After installing the battery in 60 seconds the first data packet will be sent...

Page 5: ...iptions Consumable parts replacement Yes The battery is the only part need to check the lifetime to replace Check the battery status on the back end system Cleaning device No Please refer to this link...

Page 6: ...e estimation please refer to this link measure_period Default 300s This is the time period for the wireless transmitter to wake up and take the measurement from the transducer The default value is 360...

Page 7: ..._VERSION string Read 6 6 3 2 HW_VERSION string Read 8 8 3 2 DEVICE_ID hex Read Product ID 10 A 3 4 DEVICE_PAC hex Read Product PAC 14 E 3 1 SENSOR_TYPE 1 255 uint16 Read Sensor or Input Type Read Writ...

Page 8: ...se time in second 307 133 3 16 2 C_H_FACTOR 4 4 float Read Write For methane C h 4 4 vol for propane C h 1 7 vol Please refer to this link Please refer to the detailed specifications inthis link For w...

Reviews: