12037 N Highway 99
Seminole, OK 74868
Phone (405) 382-0731
www.enviro-ok.com
www.safran‐
passenger
‐solutions.com
Copyright © 2020
Original Release
ATA 21‐00‐60
Page | 22
NOTE
: Do not disassemble the parts unnecessarily.
5.1.7. Refer to Illustrated Parts Listing (IPL) for figure/item numbers (Section 11).
5.1.8. Tools, fixtures, equipment, or consumable items required:
• Small hand tools and socket set
• Scribe or wire hook
• Volt or OHM meter (digital)
• Shop air, 40 PSIG max
• Respiration mask
5.2. Condenser Module Disassembly Procedures
5.2.1. Removal of Receiver Dryer
5.2.1.1.
Verify that system refrigerant charge has been recovered (refer to Servicing, Section
13)
5.2.1.2.
Disconnect electrical wiring to binary pressure switch.
5.2.1.3.
Disconnect refrigerant plumbing connection from receiver dryer inlet port.
5.2.1.4.
Disconnect discharge refrigerant line from receiver dryer outlet port.
5.2.1.5.
Cap receiver dryer (if reusing) and plumbing connections immediately.
5.2.1.6.
Loosen receiver dryer attaching clamp and carefully slide receiver dryer from
mounting bracket.
5.2.2. Removal of Hose Assembly
5.2.2.1.
The hose assembly has Loctite thread sealant applied. Slight heat using a heat gun
may ease loosening of the nut. Take care not to damage surrounding components with
excessive heat.
5.2.2.2.
Use a backup wrench on the condenser outlet to ensure no damage to the welds occur.