OEM
– Installation guide
Section 3 :Installation Procedure
46
This document and the information therein are the property of Morpho.
They must not be copied or communicated to a third party without the prior written authorization of Morpho
2015_2000009096 V4
May 2017
DataClock Output
Figure 22: Serial port wiring – DataClock
A
5
Digital ground
Ground for Wiegand (connect pin 5 or 6)
6
Digital ground
Ground for Wiegand (connect pin 5 or 6)
B
3
D0_OUT
Out
Data ( 5V TTL )
4
D1_OUT
Out
Clock ( 5V TTL )
RS485
Figure 23: Serial port wiring – RS485
A
5
Digital ground
Ground (connect pin 5 or 6)
6
Digital ground
Ground (connect pin 5 or 6)
D
5
RS485 TX / RX +
Out
RS485 non inverting signal
6
RS485 TX / RX -
Out
RS485 inverting signal
RS485 implementation is limited to half-duplex communication. So only Tx+, Tx- and
ground reference signals are necessary.
Depending on the RS485 network, an impedance adaptation may be required.
For farthest terminal, a 120-Ohms resistor termination may be added outside the
terminal between TX+ and TX-.