background image

 / 

22 • GA FM 1 05.01

FOG GENERATOR  FLOWMARKER

Battery

Batterie

Heating

Heizung

ready

Bereit

Multi function button: 

fog + „on“

Multifunktionstaster:   

 

Nebel + Aktivierung 

tank control window

Tanksichtfenster

Battery

Einschub-Batterie

control leD

Kontrollampen

Fill opening/filter cartridge

Befüllöffnung/Filterkartusche

Battery compartment

Batteriefach

Battery compartement safety screw

Batteriefachsicherung

Power input socket 12 V Dc

Ladebuchse 12 V DC

Figure 2 / 

Abb. 2

Use with application tube AR1

Verwendung mit Applikatorrohr AR 1

thread for application tube

Gewindeaufnahme für Applikator

Adjustment ring for air intake

Verstellring (Luftzufuhr)

Figure 1

Abb. 1

 

nozzle / 

Düse

Ar1

Summary of Contents for Tintschl Engineering FlowMarker

Page 1: ...HNE FILM FERNSEHEN G NTHER SCHAIDT SAFEX CHEMIE D 22869 SCHENEFELD BLANKENESER CHAUSSEE 26 32 TEL 040 83 92 11 0 FAX 040 830 1452 Instruction Manual Gebrauchsanleitung V 3 2 FlowMarker Flow control A...

Page 2: ...d the safety instructions befor use Diese Gebrauchsanleitung ist zweisprachig die deutsche Version finden Sie im 2 Teil Fragen zu der Anwendung beantworten wir gerne auch per Telefon oder E Mail Die S...

Page 3: ...ATIONS AND DESCRIPTION OF COMPONENTS S 4 5 Instruction Manual A System description 6 B Preparing device for operation 6 C Using FlowMarker 8 D Maintenance and care 9 E Storage and transportation 11 F...

Page 4: ...ontrollampen Fill opening filter cartridge Bef ll ffnung Filterkartusche Battery compartment Batteriefach Battery compartement safety screw Batteriefachsicherung Power input socket 12 V DC Ladebuchse...

Page 5: ...Fill opening Bef ll ffnung Pressurized can Druckgasdose Figure 4 Abb 4 Filling FLOW MARKER with FOG FLUID FLOWMARKER mit FOGFLUID bef llen Battery charger Batterie Ladeger t Fill stem F llstift Figur...

Page 6: ...crewable application tube type AR1 one pressurized can FlowMarker Fog Fluid 4 condensation absorbing rings each type KR1 and KR2 one plastic tube for removing condensation absorbing ring KR1 a low vol...

Page 7: ...ozzle or application tube pointing up Press the fog button for about 45 seconds until the fog comes out evenly De aerating can only be carried out in upward direction a To place the battery in the dev...

Page 8: ...eration within few seconds depending on the time it has not been used max 30 seconds when heat exchanger has completely cooled down To use the special advantages of the patented FlowMarker the fog app...

Page 9: ...ttery compartment safety screw hold the device upright with the nozzle showing up and slightly beat the edge of the battery compartment on the ball of the thumb of your open hand until the battery loo...

Page 10: ...fluid channels or the heat exchanger must not be removed with acid de scaling agent or other detergents this would seriously damage the device Appropriate repairs can only be carried out at the manufa...

Page 11: ...ce will dry up without leaving a residue In the application tube however it is likely that under intensive use the condensed fluid film will increase and fluid may drop out the tube To avoid a slide r...

Page 12: ...CE and therefore meet to the legal regulations of the European Community The FlowMarker fulfils international standards for low voltage operated electric devices The FlowMarker contains no hazardous...

Page 13: ...local regulations By no means open or burn the battery or short circuit the battery poles Should in case of damage any acid gel escape from the battery imme diately rinse the affected parts of the bo...

Page 14: ...e circa 16 ml Fluid consumption circa 0 7 ml min for continuous fog generation Fog performance tank volume lasts for circa 20 minutes continuous fog or for about 420 fog cycles of circa 3 seconds each...

Page 15: ...und Beschreibung der Bedienungselemente S 4 5 GEBRAUCHSANWEISUNG A Systembeschreibung S 16 B Ger tevorbereitung S 16 C Inbetriebnahme S 18 D Wartung und Pflege S 19 E Lagerung und Transport S 21 F Si...

Page 16: ...ackung FlowMarker FOG FLUID Nebelmittel je 4 Kondensat Aufnahmeringen Typ KR1 und KR2 Einem Kunstoffrohr zur Entfernung des Kondensatringes KR1 einem Stecker Ladeger t 12 V 1 A 12 VA zum Laden der Bat...

Page 17: ...ird durch ca 2 sek langes Bet tigen des wei en Knopfes aktiviert die gelbe LED HEIZUNG leuchtet dabei auf Leuchtet die rote LED Batterie auf ist die Batterie entladen und muss mind 10 Minuten mittels...

Page 18: ...cher wieder betriebsbereit Um die besonderen Vorteile des patentierten SAFEX FLOWMARKER nutzen zu k nnen ist f r impulsarme und thermisch neutrale Nebelerzeugung das Nebel Applika tionsrohr erforderli...

Page 19: ...lagen bis sich die Batterie l st und in die Handfl che gleitet Anschlie end gem Abschnitt B BATTERIE EINSETZEN S 17 eine frische Batterie verwenden Das Ger t ist nur f r den Betrieb mit Originalbatter...

Page 20: ...eben werden da bereits kleinste Partikel zu einer ernsthaften reparaturaufwendigen Besch digung des Ger tes f hren k nnen Eine Verstopfung der Fl ssigkeitswege oder des W rmetauschers kann nicht mit S...

Page 21: ...iverem Gebrauch des Ger tes wird jedoch speziell im Applikationsrohr der Niederschlag zunehmen wenn dieses nicht gut von Luft durchstr mt wird Um heraustropfendes Fluid aus dem Rohr und damit Rutschge...

Page 22: ...isierte Werkst tten Hersteller vorgenommen werden 5 In R umen mit Publikumsverkehr sollte das Ger t f r Unbefugte nicht zugriffs bereit sein Ger t und Zubeh r Fluiddose usw geh ren ebenfalls nicht in...

Page 23: ...s darf die Batterie ge ffnet verbrannt oder die Batteriepole kurzgeschlossen werden F r den Fall dass z B durch Bruch S uregel aus der Batterie austritt sind betroffene K rperpartien sofort mit reichl...

Page 24: ...X FLOWMARKER NEBELFLUID Druckgasdose Tankinhalt ca 16 ml Fluidverbrauch ca 0 7 ml min bei Dauernebelerzeugung Nebelleistung Tankinhalt reicht f r ca 20 min Dauernebel oder f r ca 420 Nebelzyklen von c...

Page 25: ...GA FM 1 03 05 22 25...

Page 26: ...26 22 GA FM 1 05 01...

Page 27: ...GA FM 1 03 05 22 27...

Page 28: ...28 22 GA FM 1 05 01...

Reviews: