background image

This manual is intended to meet the manufacturer’s instructions as

required by ANSI Z359.14 and should be used as part

of an employee training program as required by OSHA.

Copyright Safewaze 2022

 SRL Instruction Manual

220-00067

ANSI

Z359.14-2014

OSHA

Single Leg (LE)

SW8008-11LE

SW8008-11LE-RBHALU

SW8008-11LE-ALU

SW8008-11LE-RBH

Dual Leg (LE)

SW8008-11LE-DL

SW8008-11LE-RBHALUDL

SW8008-11LE-ALUDL

SW8008-11LE-RBHDL

Summary of Contents for SW-8008-11LE

Page 1: ... used as part of an employee training program as required by OSHA Copyright Safewaze 2022 SRL Instruction Manual 220 00067 ANSI Z359 14 2014 OSHA Single Leg LE SW8008 11LE SW8008 11LE RBHALU SW8008 11LE ALU SW8008 11LE RBH Dual Leg LE SW8008 11LE DL SW8008 11LE RBHALUDL SW8008 11LE ALUDL SW8008 11LE RBHDL ...

Page 2: ... or Qualified Person should always review and approve the PFAS system prior to worker use Fall protection equipment that fails inspection must be removed from service and tagged Unusable This equipment should be returned to Safewaze for repair service if applicable or destroyed For questions regarding service repair of components contact Safewaze Never exceed the maximum allowable weight capacity ...

Page 3: ...M A T E R I A L S W 9 0 1 2 B E H I N D T H E W E B B R A C K E T S T E E L R E B A R H O O K A L U M I N U M R E B A R H O O K A N S I O S H A U S E R C A P A C I T Y DESCRIPTION Table 1 indicates the SRL models included in the Latitude Edge 11 Series as well as their configurations Models in the series are offered in 11 ft 3 4 m length Latitude Edge 11 units are equipped with 3 16 galvanized ste...

Page 4: ...n some instances generate more forces than a fall with the user wearing no fall protection equipment Minimize swing falls by working as directly below the anchorage point as possible Free Fall Safewaze SRLs when used correctly with the unit anchored directly overhead and no slack in the lifeline will limit the free fall distance to 0 ft 0 cm To limit free fall distances keep attachment of the SRL ...

Page 5: ...he Inspection Form on Page 18 of this manual prior to filling out the form for the first time Copies of the Inspection Form can be used for later Inspections Annual inspections by a Competent Person other than the user must be recorded in the Inspection Log Page 19 2 2 FALL PROTECTION RESCUE PLAN When using this equipment employers must create and maintain a Fall Protection and Rescue Plan and pro...

Page 6: ...xception of Tie Back hooks NOTE Large snap hooks must not be connected to objects which will result in a load on the gate if the hook twists or rotates unless the snap hook complies with ANSI Z359 12 and is equipped with a 3 600 lbs 16 kN gate Check the marking on your snap hook to verify its compatibility In a false engagement where features that protrude from the snap hook or carabiner catch on ...

Page 7: ...eight or higher than the edge over which a fall may occur An anchor point below the level of the edge is dangerous as they cause the lifeline to redirect at a sharper than 90 degree angle See Figure 4 The user s must not work on the far side of an opening opposite the Leading Edge SRL anchor point The redirection angle of the lifeline at an edge over which a fall may occur shall be at least 90 deg...

Page 8: ...5 10 4 82 m 16 3 4 95 m 16 9 5 10 m 13 6 4 11 m 14 4 26 m 14 6 4 42 m 15 4 57 m 15 4 4 67 m 15 10 4 82 m 16 3 4 95 m 13 2 4 01 m 13 6 4 11 m 14 1 4 29 m 14 6 4 42 m 15 4 57 m X X 12 8 3 84 m 13 3 96 m 13 6 4 11 m 14 1 4 29 m X X X 17 5 18 m 17 6 5 33 m 18 5 48 m 18 9 5 71 m 19 6 5 94 m 20 3 6 17 m 21 6 40 m 16 6 5 02 m 17 4 62 m 17 7 5 35 m 18 3 5 56 m 18 9 5 71 m 19 6 5 94 m 20 3 6 17 m 16 4 87 m...

Page 9: ...lbf 6 0 kN Average Arresting Force 900 lbf 4 0 kN Claimed Maximum Arresting Distance 47 in 1 2 m Minimum Fall Clearance Required 6 5 ft 1 52 m Maximum Free Fall 0 ft 0 m Maximum Arresting Force 1 800 lbf 8 0 kN Average Arresting Force N A Claimed Maximum Arresting Distance 47 in 1 5 m Minimum Fall Clearance Required 8 5 ft 2 05 m Maximum Free Fall 0 ft 0 m TABLE 7 MINIMUM FALL CLEARANCE OVERHEAD U...

Page 10: ...8 ft 1 46 m 6 ft 1 83 m 7 3 ft 2 22 m X 0 ft 0 m 5 5 ft 1 67 m 7 9 ft 2 41 m 9 8 ft 2 98 m 11 5 ft 3 50 m X 0 ft 0 m 7 1 ft 2 16 m 10 2 ft 3 10 m 12 5 ft 3 81 m 14 6 ft 4 45 m X 0 ft 0 m 9 6 ft 2 92 m 13 5 ft 4 11 m 16 7 ft 5 09 m 19 2 ft 5 85 m X 0 ft 0 m 11 6 ft 3 54 m 16 3 ft 4 96 m 20 ft 6 09 m 23 1 ft 7 04 m A B 8 ft 2 4 m 10 ft 3 m 20 ft 6 1 m 30 ft 9 1 m 50 ft 15 2 m 70 ft 21 3 m 6 ft 1 8 m...

Page 11: ... 3 4 3 2 3 2 2 1 1 0 3 4 4 3 2 5 5 2 2 1 1 0 3 4 4 3 1 5 5 6 6 9 9 8 8 7 7 9 8 7 6 9 8 7 6 8 7 5 6 8 7 6 9 8 7 9 8 7 6 6 3 5 8 7 6 5 8 7 6 5 5 4 4 3 2 2 1 1 0 1 0 0 0 1 2 3 4 5 0 0 0 0 0 6 0 2 2 2 0 0 0 0 0 1 1 1 1 1 1 2 1 1 2 0 0 0 0 2 0 1 1 1 1 2 2 7 0 0 0 0 0 1 1 1 1 8 0 0 0 0 9 5 3 4 0 4 3 3 4 0 0 0 0 2 0 1 1 2 2 4 3 3 4 5 1 0 0 0 3 1 2 1 1 2 3 5 4 4 5 6 5 6 1 0 0 0 3 1 1 2 2 2 2 2 2 3 5 4 4 5...

Page 12: ... portion of SW 9012 is in a downward orientation relative to the harness See Dwg 1 Figure 10 2 Simultaneously depress both locking buttons A and B See Dwg 2 Figure 10 and slide the bracket open as indicated See Dwg 3 Figure 10 3 With the bracket open install dual leg retractables onto the bracket via the swivel tops of each Swivels should be hanging on the curved portion of bracket 4 While pressin...

Page 13: ...fall Upon rescue remove the SRL from use When working with an SRL always allow the lifeline to retract back into the device in a controlled manner Do not release the unit to free spin back into itself WARNING Do not tie or knot the lifeline Avoid lifeline contact with sharp or abrasive surfaces Inspect the lifeline frequently for cuts fraying burns or signs of chemical damage Dirt contaminants and...

Page 14: ...istance 24 in 0 61 m 6 2 MAXIMUM ARREST FORCE AND MAXIMUM ARREST DISTANCE SRLs documented in this instruction manual meet the following Arrest Force and Arrest Distance maximums when tested in accordance with Section 4 2 1 of ANSI Z359 14 These calculations are based upon overhead anchorage of the SRL TABLE 10 CLASS A Average Arresting Force 900 lbs 5 0kN Maximum Arresting Force 1 800 lbs 8 0 kN M...

Page 15: ...ive buildup of debris on the cable may prevent the cable lifeline from fully retracting back into the housing and create a potential free fall hazard Clean cable using an acid free oil or petroleum jelly at regular intervals Always wear gloves when servicing inspecting steel cable SRLs 7 0 MAINTENANCE SERVICING AND STORAGE IMPORTANT If the lifeline comes in contact with acids or other caustic chem...

Page 16: ...ester device Connection of this device to a full body harness is to be made to the webbing at the dorsal D ring only User must ensure that any connection to anchorage is properly secured prior to use Avoid lifeline contact with chemical thermal and or electrical hazards This product is suitable for use with horizontal lifelines and horizontal positioning Lifeline may contact sharp or abrasive edge...

Page 17: ...6 OSHA 1926 502 020047 ANSI Z359 14 ANSI A10 32 OSHA 1910 66 OSHA 1926 502 020047 Pull Handle Housing FIGURE 15 INSPECTION DIAGRAMS Hook Nose Gate Hinge Galvanized Cable Housing Label Load Impact Indicator Energy Absorber Sew In Labels Swivel Top Behind the Web Bracket ...

Page 18: ...ook Body Rivets Corrosion Pitting Nicks CONNECTORS PASS FAIL NOTE Termination Stitch Splice or Swage Cuts Fraying Broken Stitching Excessive Wear Cable Separating Bird Caging Entire Length Retracts Smoothly Test Braking Locking Function LIFELINE WEB OR CABLE SELF RETRACTING DEVICES INSPECTION FORM SELF RETRACTING DEVICES Model Number Name of Inspector Serial Number Description Signature Lot Number...

Page 19: ...Copyright Safewaze 2022 Page 19 Date Inspection Items Noted Corrective Action Initials INSPECTION LOG ...

Page 20: ...Copyright Safewaze 2022 Page 20 Safewaze 225 Wilshire Ave SW Concord NC 28025 PHONE 1 800 230 0319 FAX 1 704 262 9051 WEB safewaze com EMAIL info safewaze com ...

Reviews: