background image

17

Copyright Safewaze 2022

Fig. 9

45’ - 0 Intermediate

50’ - 1 Intermediate at 25’

60’ - 1 Intermediate at 30’

70’ - 1 Intermediate at 35’

80’ - 1 Intermediate at 40’

90’ - 1 Intermediate at 45’

120’ - 2 Intermediate at 40’

130’ - 2 Intermediate at 43’

135’ - 2 Intermediate at 45’

110’ - 2 Intermediate at 36’

100’ - 2 Intermediate at 35’

Intermediate

Post

Intermediate

Post

Intermediate

Post

Intermediate

Post

Intermediate

Post

Intermediate

Post

Intermediate

Post

Intermediate

Post

Intermediate

Post

Intermediate

Post

Intermediate

Post

Intermediate

Post

Intermediate

Post

Intermediate

Post

Intermediate

Post

Intermediate Anchorage 

The spacing and number of Intermediate Posts in this grapic 

are  based  on  the  SafeLink  system  installed  using  FS5501-5                                             

Aluminum Posts only.  

This includes end and intermediate anchorage(s).  

Summary of Contents for MOBILE SAFELINK

Page 1: ...Copyright Safewaze 2022 1 Safewaze 225 Wilshire Ave SW Concord NC 28025 info safewaze com 800 230 0319 safewaze com MOBILE HORIZONTAL LIFELINE SYSTEM USER MANUAL MANUAL SafeLink...

Page 2: ...AFELINK SYSTEM INTRODUCTION 3 2 SAFELINK SYSTEM DESCRIPTION 3 3 SAFELINK SYSTEM OVERVIEW AND CONNECTIONS 4 4 USER INSTRUCTIONS AND LIMITATIONS 5 5 PRIOR TO USE 6 6 ANCHORAGE REQUIREMENTS 6 7 CONNECTIO...

Page 3: ...502 ANSI A10 32 225 Wilshire Ave SW Concord NC 28025 P 800 230 0319 or F 704 262 9051 WWW SAFEWAZE COM ANSI Z359 14 ANSI A10 32 OSHA 1910 66 OSHA 1926 502 SELF RETRACTING LANYARD SELF RETRACTING LANYA...

Page 4: ...tion for SafeLink Horizontal Lifeline System PVC Sleeve is inserted into pre poured concrete and aluminum posts are inserted into PVC sleeve or SafeLink Post Baseplates PVC Sleeve FS EX2504 Fig B Cros...

Page 5: ...t a fall occurs on the SafeLink System the system must be removed from service USE LIMITATIONS 1 The Safewaze Mobile SafeLink Horizontal Lifeline System is designed for up to four 4 users at one time...

Page 6: ...which maintains a safety factor of at least two 2 feet and must be installed and used as outlined by the qualified person Safewaze according to the Mobile SafeLink Horizontal Lifeline System User Manu...

Page 7: ...east 5 000 lbs 2267 97 kg per employee attached or shall be designed installed and used as follows as part of a complete personal fall arrest system which maintains a safety factor of at least two 2 a...

Page 8: ...six 6 9 rebar or larger Aluminum post is placed into the attached sleeve K FormLink FS EX2502 Constructed with 6061 T6511 aluminum the FormLink can be used in three 3 different applications 1 It can b...

Page 9: ...possible request that a column tie be located approximately 2 in 50 88 mm below the top surface of the column pour Only one tie shown in Fig 1 for clarity The aluminum post is 7 ft 6 in 2 29 m long Wi...

Page 10: ...the stop lever is contacted Continue to apply pressure against the stop lever until it releases and allow the handle to pivot backward Repeat this procedure to release the load a notch at a time Tens...

Page 11: ...g 400 lbs 181 4kg 400 lbs 181 4kg 600 lbs 272 2kg 600 lbs 272 2kg 650 lbs 295kg www safewaze com OSHA 1926 502 ANSI A10 32 ALUMINUM POST FS EX5501 5 CARABINER FS1015 CARABINER FS1015 STOPLINK BRAKE 01...

Page 12: ...strates an appropriate application when the stanchion is set back from the edge Table 1 gives the safe working height which varies with distances D and B as indicated in Figure SA 2 An Interior applic...

Page 13: ...intended for use as part of a complete personal fall protection system Use in any other application including but not limited to material handling recreational or sprots related activities or other ac...

Page 14: ...to high heat caustic chemicals corrosive environments high voltage power lines explosive or toxic gases moving machinery or overhead materials that may fall and contact the user or fall arrest system...

Page 15: ...w safewaze com OSHA 1926 502 ANSI A10 32 Distance from walking working surface Clearances are calculated using only the SafeLink Horizontal Lifeline System fully assembled per the User Manual Installa...

Page 16: ...ements DO NOT attach fixed length lanyard equipment to this system SafeLink System with 2 Energy Absorbers Fall Clearance Chart In the event that the SafeLink System is installed with 2 Inline Energy...

Page 17: ...te at 35 Intermediate Post Intermediate Post Intermediate Post Intermediate Post Intermediate Post Intermediate Post Intermediate Post Intermediate Post Intermediate Post Intermediate Post Intermediat...

Page 18: ...of users to one 1 as outlined NOTE If using standard FS EX5501 5 posts as intermediate anchorages i e embedded in concrete the number of users can be up to four 4 per system Intermediate anchorage co...

Page 19: ...g of the dual leg SRL to the cable using a metal O ring or approved carabiner of the Mobile SafeLink Horizontal Lifeline System Attach the unused leg to the lanyard storage keeper on the full body har...

Page 20: ...ifeline System shall be inspected before each use and annually by a competent person as required by the OSHA standards If inspection reveals any defect inadequate maintenance or unsafe condition remov...

Page 21: ...duct lifetime is indefinite as long as it passes pre use and Competent Person inspections User must inspect prior to each use Competent Person other than the user must complete formal inspection at le...

Reviews: