Minimum Required Fall Clearance:

The Minimum Required Fall Clearance distances indicated in Table 7 are based upon Ambient, Wet, Hot, and Cold testing results for each unit in the 

Latitude Pro SRL-P series.  Fall Clearances indicated in Table 7 are calculated using the greatest Actual Arrest Distance out of the four tests performed.  

Table 6 indicates the specific arrest distance in prescribed condition testing with 0’ offset.  

EXAMPLE:  

The Latitude Pro SRL-Ps have Actual Arrest Distances of 22”, 21”, 22”, and 23” during Ambient, Wet, Hot, and Cold testing respectively.

By using the greatest distance (Cold=23”) out of the four tests performed and inserting that value in Row B of the Chart in Figure 2, a Total Fall Clearance  

of 5’ 11” is required.  

FIGURE 1 - CLASS 1 SRL AXES DIAGRAM

Y

X

Z

Z:

 

Minimum Required 

Fall Clearance From 

Walking/Working Surface 

X:

 SRL Anchorage Height

       Above Dorsal D-ring

Y:

 Lateral Offset 

      Distance

Class 1 Axes Diagram

Model

Ambient

Wet

Hot

Cold

Latitude Pro Series SRL

22”

21”

22”

23”

Latitude Pro Tie-back Series SRL

22”

21”

22”

23”

NOTE:

  A Qualified Person must determine if MRFCs can be adjusted based upon actual jobsite atmospheric conditions or additional 

factors.  

Model

MRFC

Latitude Pro Series SRL

5’ 11” (1.8 m)

Latitude Pro Tie-back Series SRL

5’ 11” (1.8 m)

Fall Clearance:  

There must be sufficient clearance below the anchorage connector to arrest a fall before the user strikes the ground or an obstruction.  

 

Figure 2 illustrates a typical Fall Clearance calculation based on the ANSI Z359.14-2021 prescribed Maximum Allowed Free Fall of 24 in. and Maximum Allowed 

Arrest Distance of 42 in.  Fall Clearance calculations may vary dependent upon the SRL being used.  It is essential that the correct Arrest Distance is used to 

determine Minimum Required Fall Clearance.    

Personal Fall Arrest: 

Safewaze Class 1 SRLs can be used as part of a complete Personal Fall Arrest System (PFAS) for a maximum of one user.  Only one user 

may be connected to an SRL.  Avoid sharp and/or abrasive edges. If contact with an abrasive surface is unavoidable, proper edge protection must be used.  The 

structure utilized for attachment must be capable of withstanding a load of 5,000 lbs. in all directions permitted by the system. The maximum allowable free fall 

is 2 ft.    

 10.0  ACTUAL ARREST DISTANCE / MINIMUM REQUIRED FALL CLEARANCE

Safewaze SRLs are tested in accordance with ANSI Z359.14-2021 conditioning test protocols.  Table 6 reflects the actual performance of each unit in the 

Latitude Pro SRL-P series when subjected to Ambient, Wet, Hot, and Cold testing.  The Fall Clearance specifications in Table 8 of this manual reflect the 

 

ANSI Z359.14-2021 Maximum Arrest Distance allowance of 42”.  Actual Arrest Distances for each unit in the Latitude Pro SRL-P series are indicated below.  

These Actual Arrest Distances are typically lower than the 42” maximum as specified per ANSI. In certain instances this may allow for a Qualified Person to 

adjust Minimum Required Fall Clearances indicated in Table 8.

Actual Arrest Distance (AD):

TABLE 7 - ANSI ABOVE D-RING MINIMUM REQUIRED FALL CLEARANCE (MRFC)

TABLE 6 - ANSI ABOVE D-RING ACTUAL ARREST DISTANCES 

Summary of Contents for LATITUDE PRO SRL-P Series

Page 1: ...This manual is intended to meet the manufacturer s instructions as required by ANSI Z359 14 2021 and should be used as part of an employee training program as required by OSHA SRL P Instruction Manual...

Page 2: ...EST DISTANCE MIN REQ FALL CLEARANCE 8 10 11 0 SWING FALLS 11 12 0 FALL PROTECTION AND RESCUE PLAN 12 13 0 NORMAL OPERATIONS 12 14 0 COMPATIBILITY OF COMPONENTS 12 15 0 COMPATIBILITY OF CONNECTORS 12 1...

Page 3: ...or both that may affect or interfere with the safe function of each other DO NOT alter equipment DO NOT misuse equipment User must have a written Rescue Plan and means at hand to implement it when us...

Page 4: ...10 1 S 7 Dyneema Webbing 7X 05 Clear Resin 3 7 X X 018 5011 1 S 7 Dyneema Webbing 7X 05 Clear Resin 3 3 X X 018 5012 1 S 7 Dyneema Webbing 7X 05 Clear Resin 2 5 X X 018 5013 1 S 7 Dyneema Webbing 7X 0...

Page 5: ...s 1 and 2 Class 1 Self retracting devices which shall be used only on overhead anchorages and shall be subjected to a maximum free fall of 2 feet 0 6 m or less in practical application Class 2 Self re...

Page 6: ...Figure 2 Illustrates a Fall Clearance Calculation Fall Clearance FC is the total combined values of Free Fall FF Deceleration Distance DD and a Safety Factor SF Safety Factor calculations may differ...

Page 7: ...on assigned by the employer to perform duties at a location where such person will be exposed to a fall hazard 2 Rescuer Person or persons other than the rescue subject acting to perform an assisted r...

Page 8: ...pical Fall Clearance calculation based on the ANSI Z359 14 2021 prescribed Maximum Allowed Free Fall of 24 in and Maximum Allowed Arrest Distance of 42 in Fall Clearance calculations may vary dependen...

Page 9: ...DISTANCE OF 42 Lateral Offset Distance Y In Feet 0 2 4 6 8 10 15 20 25 8 7 6 2 3 m 8 3 2 5 m 9 2 7 m 10 1 3 1 m 11 4 3 5 m 12 9 4 m 17 1 5 2 m 21 6 6 6 m 26 3 8 m 10 7 6 2 3 m 8 3 2 5 m 8 9 2 7 m 9 8...

Page 10: ...ovides the Maximum Allowed Distance below the D ring a Latitude Pro SRL P may be used as well as the Actual Arrest Distance as tested for each unit Both are factored into the MRFC calculation NOTE Min...

Page 11: ...d above the user s Dorsal D ring The X Axis represents lateral movement of the worker in relation to the SRL Example Latitude Pro SRL P Anchored Overhead This example represents the user anchored 5 Ov...

Page 12: ...ECTORS HAVE ADDITIONAL REQUIREMENTS CONTACT SAFEWAZE WITH QUESTIONS Connectors are compatible with connecting elements when they have been designed to work together in such a way that their sizes and...

Page 13: ...the effects of a fall must be removed from service immediately Equipment must then be serviced See Section 18 if applicable or disposed of See Section 19 16 0 USE 16 1 OPERATION 16 2 AFTER A FALL A f...

Page 14: ...ch Swivels should be hanging on the curved portion of bracket 4 Slide the bar behind both loops of webbing at dorsal D ring Swing the bracket closed unti it locks into place 5 Check the locking functi...

Page 15: ...emicals remove the SRL from service and wash with water and a mild soap solution Inspect the SRL using the Inspection Form on Page 18 before returning to service 18 0 MAINTENANCE SERVICE AND STORAGE 1...

Page 16: ...orce 900 lbs 408 23 kg Max Arrest Distance 42 in 106 68 cm Actual Arrest Distance 23 in 58 42 cm Actual Arrest Distance 23 in 58 42 cm Use Below D ring Not permitted Use Below D ring 2 ft 61 m Max Fre...

Page 17: ...14 OSHA 1910 140 OSHA 1910 66 020052 FIGURE 13 INSPECTION DIAGRAMS Webbing Housing Labeling Labeling Labeling Labeling Labeling Swivel Top Snaphook Labeling Cover Hook Body Hook Body Load Impact Indic...

Page 18: ...ok Body Rivets Corrosion Pitting Nicks CONNECTORS PASS FAIL NOTE Termination Stitch Splice or Swage Cuts Fraying Broken Stitching Excessive Wear Cable Separating Bird Caging Entire Length Retracts Smo...

Page 19: ...Copyright Safewaze 2023 Page 19 Date Inspection Items Noted Corrective Action Initials INSPECTION LOG...