background image

     

Safewaze  

225 Wilshire Ave SW

Concord, NC 28025

PHONE:  1-800-230-0319

FAX: 1-704-262-9051

WEB: Safewaze.com

EMAIL: [email protected]

019-1080

020-1262

020-1285

020-1348

SW77125-UTQC-SL

019-1081

020-1263

020-1286

020-1349

SW77225-UT2QCSL

019-1082

020-1264

020-1287

020-1350

SW77225-UT3QC

019-1083

020-1266

020-1288

020-1352

SW77225-UTQC

020-1160

020-1267

020-1290

020-1353

SW88125-XUT-4QC

020-1161

020-1268

020-1291

020-1354

020-1162

020-1269

020-1292

020-1355

020-1163

020-1270

020-1293

020-1356

020-1164

020-1271

020-1294

020-1357

020-1250

020-1272

020-1295

020-1358

020-1251

020-1274

020-1296

021-1562

020-1252

020-1275

020-1306

021-1563

020-1253

020-1276

020-1307

021-1564

020-1254

020-1277

020-1308

021-1565

020-1255

020-1278

020-1309

021-1566

020-1256

020-1279

020-1310

021-1567

020-1258

020-1280

020-1344

021-1568

020-1259

020-1282

020-1345

021-1569

020-1260

020-1283

020-1346

021-1656

020-1261

020-1284

020-1347

SW77125-UTQC

Part Numbers Covered in this Manual

Summary of Contents for Arc Flash 019-1080

Page 1: ...ach component of the system The user must read and understand these instructions before using this equipment Manufacturer s instructions must be followed for proper use and maintenance of this equipme...

Page 2: ...STANDARDS 3 4 0 WORKER CLASSIFICATIONS 3 5 0 PURPOSE 3 6 0 LIMITATIONS REQUIREMENTS 3 6 7 0 COMPATIBILITY OF COMPONENTS 6 8 0 COMPATIBILITY OF CONNECTORS 6 9 0 MAKING CONNECTIONS 7 10 0 BUCKLE TYPE AN...

Page 3: ...ipment for an application not specified in this manual contact Safewaze technical support Additional precautions should be used when working in environments of high heat electrical hazards chemical ha...

Page 4: ...AS that requires a properly rated anchorage and connector that in conjunction with an appropriate connecting device meets the fall protection requirement 2 0 APPLICATION 2 1 HARNESS CONNECTION POINTS...

Page 5: ...surroundings or working conditions which are unsanitary hazardous or dangerous to employees and who has authorization to take prompt corrective measures to eliminate them Authorized Person Authorized...

Page 6: ...knowledge is capable of identifying evaluating and addressing existing and potential fall hazards and who has the employer s authority to take prompt corrective action with regard to such hazards NOTE...

Page 7: ...connecting device to use The lower the clearance height the less options available to connect to the anchor point with To Determine Fall Clearance several factors must be considered Length of Anchorag...

Page 8: ...tible in size shape and strength Self locking snap hooks and carabiners are required by ANSI Z359 and OSHA guidelines Contact Safewaze if you have any questions about compatibility NOTE SOME SPECIALTY...

Page 9: ...ners are designed to be used only as specified in each product s user s instructions See Figure 5 for examples of inappropriate connections Do not connect snap hooks and carabiners To a D ring to whic...

Page 10: ...of 6 ft 1 83 m In instances where a 12 ft 3 66 m is likely the Safewaze FBH can be used provided that the Safewaze Energy Absorber Lanyard utilized is rated for extended free falls Arborist Use Safewa...

Page 11: ...nsion of the strap See Figure 6 for Pass Through Buckle Operation Step 5 If FBH is equipped with a waist belt adjust length in same manner as grommet leg and fasten for snug fit Safewaze harnesses are...

Page 12: ...gure 9 Dwg 2 and slide the bracket open as indicated See Figure 9 Dwg 3 3 With the bracket open install dual leg retractables onto the bracket via the swivel tops of each Swivels should be hanging on...

Page 13: ...Dwg 3 3 With the bracket open install dual leg retractables onto the bracket via the swivel tops of each Swivels should be hanging on the curved portion of bracket 4 Slide the bar behind both loops o...

Page 14: ...g on the X Pad of harness Ensure that both loops of webbing on X Pad are inside of carabiner 5 With carabiner gate still open slide the removed retractable and green spacer back onto carabiner and all...

Page 15: ...14 ANSI A10 32 OSHA 1910 66 OSHA 1926 502 Fall Arrest Systems Confined Space Engineering Rescue Systems 6 6 WWW SAFE WAZE COM SEL F RET RAC TING LAN YAR D SEL F RET RAC TING LAN YAR D ANSI Z359 14 AN...

Page 16: ...arness for indications that it has been exposed to fall arrest forces All Safewaze FBH s are equipped with two load indicators one on each back torso strap If either of the load indicators have been d...

Page 17: ...ng 5 Inspect dorsal D ring assembly Ensure that dorsal D ring has no excessive corrosion and that web loop is intact with no cuts fraying or damage 6 Check that load indicators are present on harness...

Page 18: ...ack Straps Cuts Burns Holes Paint Contamination Excessive Wear Heat UV Damage Shoulder Chest Leg Back Straps PASS PASS PASS PASS FAIL FAIL FAIL FAIL NOTE NOTE NOTE NOTE LABELS MARKINGS HARDWARE Buckle...

Page 19: ...User Manual V1 0 2021 Copyright Safewaze 17 FIGURE 15 LABEL EXAMPLES JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 19 0 LABELING...

Page 20: ...C 020 1161 020 1268 020 1291 020 1354 020 1162 020 1269 020 1292 020 1355 020 1163 020 1270 020 1293 020 1356 020 1164 020 1271 020 1294 020 1357 020 1250 020 1272 020 1295 020 1358 020 1251 020 1274...

Reviews: