Safety Technology International STI-6400 Exit Stopper Instruction Manual Download Page 5

5

I

NSTALLATION

I

NSTRUCTIONS

Note: STI recommends setting up unit and testing settings prior to mounting. 

1. Make  sure  key  switch  is  in  the  OFF

position.

2. Remove  tamper  screw  on  side  of

unit  and  remove  housing  cover.
Save  this  tool  for  future  servicing
and battery change (Figure 2).

3. Set  switches,  on  circuit  board,  to

desired alarm settings (figure 1).

4. Test  settings  by  connecting  battery

or  external  power  source.    If  using
external  power  source  a  Class  II  UL
Listed  transformer  is  required.    If
power  is  present  at  terminal  block
(figure  1)  9V  battery  is  in  no-load
on standby power consumption.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

19039 SCREW

6 x 1 1/4 in.

(2) PROVIDED

19018 ANCHOR
(2) PROVIDED

BOTTOM SURFACE AS SHOWN

WIRES THROUGH NOTCH ON

AND ROUTE REED SWITCH

REMOVE FRONT COVER

VIEW SHOWING MAGNET INSTALLATION

MAGNET

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

   

 

 

 

 

 

 

     

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MAXIMUM GAP 3/4 in. (19mm) 
3/8 in. (9.5mm) ON METAL DOOR
AND FRAME

SPACERS (USE AS NECESSARY)
NOTE: 2 SPACERS UNDER BOTH
MAGNET AND REED SWITCH
MUST BE USED ON STEEL DOORS

 

 

 

 

FIGURE 2

FIGURE 3

A

LARM

F

EATURE

D

ESCRIPTION

• 

Volume Switch JP2

- Sets alarm volume to high 105 dB or low 95 dB. 

• 

Duration Switch JP3 and JP4

- Amount of time alarm sounds after trip.  Arming resets at end

of duration if door is closed.  Alarm will not reset if in continuous mode; alarm sounds until
battery is drained.  Annunciator Mode is a series of 10 short beeps or until door is closed.

• 

Trip  Delay  Switch  JP5

-  If  you  wish  to 

ENTER

an  alarmed  door  without  sounding  the  horn

immediately, the trip delay will allow 15 seconds for you to enter and de-activate the alarm
with the key switch before the alarm will sound.

• 

Arming  Switch  JP7

-  This  mode  is  useful  when  an 

AUTHORIZED  EXIT

is  required  through

alarmed door.  In “ON” position immediate arming will set the alarm ready to function as soon
as door is opened.  In “OFF” position delay arming will allow 15 seconds for you to exit through
the door without sending alarm signal.

5. Mount main unit on or next to door using

hardware provided. Reed switch mounting
locations can be moved to one of the four
positions  shown  in  figure  2.    If  mounted
next  to  door,  route  reed  switch  wire
through knockout in bottom of housing as
shown in figure 3.

6.Mount  magnet  on  door  frame  (or  door  if

unit is mounted next to door) using screws
provided.  When mounting on metal doors
or  door  frames,  use  plastic  spacers
provided.    Reed  switch  and  magnet  must
be within 3/4” when door is closed (3/8”
on metal door and frame).  Please refer to
figures  4,  5  and  6  on  page  6  for  other
mounting options.

7. If installing STI-6402, STI-6403, or STI-6404

continue  to  page  7  for  more  instructions
(Figures  7  and  8).  STI-6402  mounting
option is shown on page 6.

8. Replace cover by sliding flanges on inside

of cover into slots on base. Then rotate the
cover  over  unit  and  snap  close.  Replace
tamper screw.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

   

FLANGES

SLOTS

TERMINAL STRIP

9 VOLT BATTERY

19011 TAMPERPROOF SCREW
(1) PROVIDED

19016 TAMPER WRENCH
(1) PROVIDED

BASE

COVER

19014 MOUNTING SCREW

(4) PROVIDED

EMERGENCY EXIT ONLY

STOP

STOP

ALARM SOUNDS WHEN DOOR IS OPENED

ON

OFF

 

     

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

   

 

 

 

 

 

 

     

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for STI-6400 Exit Stopper

Page 1: ...vent both unauthorized exits and entries through emergency exit doors Easy to install Less expensive than heavy horizontal bar type units and practical for all emergency doors May be mounted on top ri...

Page 2: ...hree STI 6403 may be used in parallel All specifications and information shown are current as of publication and subject to change without notice Warnings and Cautions Page 2 Warranty Information Page...

Page 3: ...30 VDC or VAC 1 Amp Stand by Current 10uA Alarm Current 130mA at 95 dB 200mA at 105 dB Electronics STI 6403 and STI 6404 Remote Horn Unit Power Source 9 VDC Operating Power only Horn Volume at 1 ft 9...

Page 4: ...OFF Duration 180 Second Alarm OFF ON Duration Continuous Alarm ON OFF Duration Annunciator Mode ON ON Trip Immediate OFF Trip 15 Second Delay ON Arming Immediate ON Arming 15 Second Delay OFF FEATURE...

Page 5: ...oor without sounding the horn immediately the trip delay will allow 15 seconds for you to enter and de activate the alarm with the key switch before the alarm will sound Arming Switch JP7 This mode is...

Page 6: ...SPACERS MUST BE USED ON STEEL DOORS 19039 SCREW 6 x 1 1 4 in 2 PROVIDED MAGNET 6400 UNIT DOOR STOP SWING DOOR TYPICAL RECESSED MOUNT DOOR JAM INSTALLATION 3 4 in 19 mm MAXIMUM GAP 3 8 in 9 5mm ON META...

Page 7: ...es STI provides 6 ft which can be cut to desired length 2 Connect first reed switch in RS1 and second in RS2 Figure 7 Refer to Figure 1 for additional details on page 4 3 If not using extra reed switc...