background image

Safetrust Inc. | 

safetrust.com

[email protected]

FCC:

  This  device  complies  with  part  15  of  the  FCC  Rules.  Operation  is

subject  to  the  following  two  conditions:  (1)  This  device  may  not  cause
harmful  interference,  and  (2)  this  device  must  accept  any  interference
received, including interference that may cause undesired operation. 

Canada  Radio  Certification: 

This  device  complies  with  Industry  Canada

license-exempt RSS standard(s). Operation is subject to the following two
conditions: (1) this device may not cause interference, and (2) this device
must  accept  any  interference,  including  interference  that  may  cause
undesired operation of the device.

Le présent appareil est conforme aux CNR d’Industrie Canada applicables
aux  appareils  radio  exempts  de  licence.  L’exploitation  est  autorisée  aux
deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage,
et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique
subi,  même  si  le  brouillage  est  susceptible  d’en  compromettre  le
fonctionnement.

CE Marking:

 Safetrust hereby declares that these proximity readers are in

compliance with the essential requirements and other relevant provisions
of Directive 1999/5/EC.

Summary of Contents for 8845-200

Page 1: ...8845 200 Quickstart Guide Last Updated November 2021 ...

Page 2: ...Contents In the box What you ll need Installation Configuration Testing Regulatory Support 01 02 03 04 05 06 07 Safetrust Inc safetrust com sales safetrust com ...

Page 3: ...01 Safetrust Inc safetrust com sales safetrust com In the box ...

Page 4: ...ust com 6 32 x 375 Phillips machine screws For mounting wall bracket 6 32 x 375 spanner security screw Option 1 Secures the top and bottom casing together 6 32 x 375 phillips flat head screw Option 2 Secures the top and bottom casing together ...

Page 5: ...02 Safetrust Inc safetrust com sales safetrust com What you ll need ...

Page 6: ...ctor Wiegand 4 conductor Twisted Pair Over All Shield and UL approved Belden3107A or equivalent OSDP Linear DC power supply Metal or plastic junction box Drill with various bits for mounting hardware Safetrust Inc safetrust com sales safetrust com ...

Page 7: ...03 Safetrust Inc safetrust com sales safetrust com Installation ...

Page 8: ...ocate the electrical box which will be recessed into the wall You will see a top and bottom metal flange with holes which is used to secure the back plate to the wall Using the Phillips machine screws provided 6 32 x 375 screw the back plate against electrical box so that it s flush ...

Page 9: ... connect the wires as per the wiring table above Ground Wiegand Output D0 Wiegand Output D1 Buzzer Input Tamper Out Green LED Input Relay Out Relay In RED LED Input RS485 B RS485 A 12 VDC Black White Green Yellow Purple Orange Blue Grey Brown Pink Aqua Red Wire Colors ...

Page 10: ...Safetrust Inc safetrust com sales safetrust com IOnce the back plate has been fitted and the wiring is complete the top casing can be inserted onto the bottom casing like shown above ...

Page 11: ...Safetrust Inc safetrust com sales safetrust com Complete the hardware installation by fixing the snake eye screws security screws to the top and bottom casing 6 32X5 16 SS ...

Page 12: ...04 Safetrust Inc safetrust com sales safetrust com Configuration ...

Page 13: ...Safetrust Inc safetrust com sales safetrust com Open the Safetrust Wallet APP and select Manage Sensor tab Make sure your system admin has set you up with this role ...

Page 14: ...Safetrust Inc safetrust com sales safetrust com With the Admin Installer tab open from the App bring the phone in range of the IoT Sensor and once visible from the App highlight and select Configure ...

Page 15: ...es safetrust com Choose an Identity System Specify the Type of access from the dropdown eg Door Gate etc Assign a short Name and Description using alphanumeric characters Choose an Output for the sensor the default is set to Wiegand ...

Page 16: ...m sales safetrust com When the IoT Sensor information is saved successfully to Credential Manager and assigned to the Identity System the new description will appear in the Manage Sensor tab with a unique serial number assigned ...

Page 17: ...05 Safetrust Inc safetrust com sales safetrust com Testing ...

Page 18: ...st Inc safetrust com sales safetrust com Status LED Solid red Indicates idle mode Flashing red Powering up Solid green Success Flashing green Credential is read and access is granted LED Ring Access with cards ...

Page 19: ...st Inc safetrust com sales safetrust com Status LED Solid red Indicates idle mode Flashing red Powering up Solid Blue Success Flashing Blue Credential is read and access is granted LED Ring Access with mobile ...

Page 20: ...06 Safetrust Inc safetrust com sales safetrust com Regulatory Information ...

Page 21: ...y not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit ...

Page 22: ...com sales safetrust com Support Thank you for purchasing the Safetrust IoT Sensor Wall Mount If for any reason you need assistance with your installation please contact your local Sales representative Sincerely The Safetrust Team ...

Page 23: ...www safetrust com support ...