SafeNet ProtectServer Internal Express 2 Installation Manual Download Page 13

 

 

Solution 

Confirm that the adapter(s) are firmly seated in the PCI slot, then uninstall the PCI 
HSM Access Provider package. Following this, perform a fresh install of the PCI 
HSM Access Provider package. 

Problem 

When operating multiple adapters under Windows 2000 or later, the adapters run 
slowly or even stall. Some commands may work correctly on one adapter, but not the 
other. 

Solution 

This problem may be resolved by resetting the configuration data in the host system 
BIOS. 

Simple Fault Diagnosis 

Fault Diagnosis Utilities 

To carry out simple fault diagnosis, SafeNet hardware maintenance utilities can be 
used. These are installed as part of the ProtectServer

 

PCI HSM Access Provider 

installation. There are two utilities: 

hsmstate

 and 

hsmreset

 

Further information about these utilities, beyond what is covered in this chapter, can 
be found in the 

Hardware Security Module Access Provider Install & Configuration 

Guide.

 

Fault Diagnosis Procedure 

From a command prompt, execute 

hsmstate

.  The output from the utility should include 

“... NORMAL mode, Responding”. 

 

If

 

the utility reports

 

“... HALTED due to a failure”: 

o

 

Execute 

hsmreset

o

 

Following the reset, check to see if the 

hsmstate

 is now reporting 

NORMAL operation. 

 

If

 

the utility

 

reports

 

“... waiting for tamper cause to be removed”: 

o

 

Check to see that external tamper detectors connected to the board are correctly 
configured if these are being used. 

o

 

Make sure the adapter is sitting firmly and correctly in the PCI slot. 

Summary of Contents for ProtectServer Internal Express 2

Page 1: ...ProtectServer Internal Express 2 PSI E2 Installation Guide...

Page 2: ...FCC compliance only devices also known to comply should be connected to the adapter s serial ports If such devices do not feature their own cables shielded cables must be used Disclaimer SafeNet makes...

Page 3: ...b www safenet inc com Support and Down loads www safenet inc com support Provides access to the SafeNet Knowledge Base and quick downloads for various products Technical Support Customer Portal https...

Page 4: ...alling the Adapter 5 PCI HSM Access Provider Installation 5 Smart Card Reader Installation 5 Completing Installation 6 Chapter 3 Troubleshooting 7 Overview 7 Known Issues 7 Problem 7 Solution 7 Proble...

Page 5: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Page 6: ...s Manual This manual is provided as an instructional aid for the installation of a ProtectServer cryptographic services hardware adapter Installation of the associated SafeNet PCI HSM Access Provider...

Page 7: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Page 8: ...on the ProtectServer adapter detailed at the beginning of Appendix A 4 Install the PSI E2 card in the host computer system 5 Install the PCI HSM Access Provider package that includes the device drive...

Page 9: ...losing the keys Note Disconnecting the battery deletes all key material on the HSM Ensure that you back up you HSM before disconnecting the power The keys are not deleted immediately Capacitors conti...

Page 10: ...detection device route the cable to it before closing the computer cover PCI HSM Access Provider Installation After successful installation of the adapter the next steps are to 1 Install the SafeNet...

Page 11: ...en the card reader and a standalone powered USB hub Again the USB connection is for power only No data transfer occurs Completing Installation Following the PCI HSM Access Provider installation to mak...

Page 12: ...ion or is left in an unstable state Solution This fault can occur if there are no free IRQs that can be assigned to the device Make sure the device is assigned an IRQ The IRQs assigned to devices are...

Page 13: ...lled as part of the ProtectServer PCI HSM Access Provider installation There are two utilities hsmstate and hsmreset Further information about these utilities beyond what is covered in this chapter ca...

Page 14: ...tamper device s two wire cable in order to insert into the tamper detection socket on the ProtectServer adapter Crimp a pair of Molex 50212 8100 2mm WTB crimp terminals to the ends of the wires comin...

Page 15: ...owered system The RTC performs a check of battery level daily If a low battery warning is detected on a PSI E2 adapter that has been un powered removed from a system then the data in the memory can be...

Reviews: