24
TTR v.2.04 EN
Configuration
OTHER CODES
CODE DATA COMMENTS
Outputs
*88*
- #
0 = Standard (Default)
•
Relay 1 will be activated when set time reached.
•
Relay 1 will be deactivated when emergency call ends.
• Relay 2 will be activated when the battery test has failed.
• Relay 2 will be deactivated by pressing the reset button.
1 = EN81-28 Pictograms
• Relay 1 will be activated when the emergency button in
pressed (yellow pictogram).
• Relay 1 will be deactivated when the reset button is
pressed or if alarm centre presses “5”.
• Relay 2 will be activated when the call is acknowledged
(green pictogram).
• Relay 2 will be deactivated when the call is disconnected.
2 = DTMF-controlled
The relays can be activated remotely for 5 seconds.
• Relay 1 will be activated for 5 seconds when DTMF “8” is
pressed.
• Relay 2 will be activated for 5 seconds when DTMF “9” is
pressed.
3 = Manual - ECF
•
Relay 1 will be activated when set delay reached.
•
Relay 1 will be deactivated when the reset button is pressed.
Change password
*91*
- - - - # Change password (default=0000)
Simulate an alarm event *94*
- #
Triggers an alarm event after programming is terminated.
1 = Emergency call
2 = Test alarm
3 = Battery failure
4 = Microphone/Loudspeaker failure
5 = Emergency call
6 = Maintenance
7 = Main unit power failure
8 = Stuck button
Reset to default
settings
*99*
- #
1 = Factory default
2 = Default P100(
The following codes will be set):
*21*0#, *22*0#, * 27*03#, *80*1#, *84*1#, *88*1#
3 = Default CPC(The following codes will be set):
*21*3#, *22*3#, *27*03#, *80*1#, *84*1#, *88*1#
4 = Default VOICE(The following codes will be set):
*21*1#, *22*1#, * 27*03#, *80*1#, *84*1#, *88*1#