ALARM TYPE
CODE DATA
COMMENTS
Alarm type 1st number
*41* - - #
Only when using CPC as alarm protocol
Normally 10 or 27, check with your alarm
company!
Alarm type 2nd number
*42* - - #
Alarm type 3rd number
*43* - - #
Alarm type 4th number
*44* - - #
Alarm type LMS
*45* - - #
Normally 17
Alarm type Test alarm
*46* - - #
Normally 26
OTHER CODES
CODE DATA
COMMENTS
Repeated alarm
*39* -#
Repeated alarms: Battery failure, Mic/
Speaker failure, Stuck button.
Alarm action repeats every 24h until the
problem is resolved.
0 = Off (default)
1 = On
External inputs
- Function
*73* - - #
The first number selects the input, i.e. Input 1
or Input 2.
The second number selects the
function.
0 = None
1 = Filter
2 = LMS/SMS
3 = Clear/Maintenance
4 = Fire Mode (default = input 2)
5 = Alarm Button (default = input 1)
6 = Call Delay
External inputs
- Input N/O or N/C
*74* - - #
T
he first number selects the input, i.e. Input 1
or Input 2.
The second number selects N/O (0) or N/C
(1).
Defult = N/O
Unit number
*82*
- #
U
nit number [0] is set by default, and means
that the unit will respond immediately.
Alarm button delay time
*87* - - #
00-25 seconds. Default = 05
Outputs (Relay)
*88* - - #
The first number selects the relay output,
i.e. Relay 1 or Relay 2. The second number
selects the function. For SW 4.00 or later, the
following parameters are used:
0 = Alarm status outputs
(default relay 1)
1 = Battery failure
(default relay 2)
2 = Pictogram (Relay 1: yellow, relay 2:
green)
3 = Activate with DTMF 8/9
(relay 1 - DTMF 8, relay 2 - DTMF 9)
4 = Manual reset
5 = Emergency call failure
6 = System failure
7 = Emergency bell