p.13
25
English
ENGLISH
Most used parameter list
- for full list see installation manual
Configuration
Code Data
Comments
Enter configuration mode
00
Enter password
* - - - - #
Default = 0000
Exit configuration mode
*00*#
Alarm
Code Data
Comments
P100 ID code
*01* - - - - - - - - #
P100 is always 8 digits
CPC ID code
*02* - - - - - - #
CPC 6-8 digits
Q23 ID code
*03* - - - - - - - - -- - #
Q23 is always 12 digits
Telephone numbers
Code Data
Comments
1st Phone number
*11* - - - - - - - - - #
Phone number to alarm receiver: 1-20
digits. Each asterisk (*) is equal to one
second delay.
Example #1: *11*0**1234567#
Example #2: *11*# deletes the phone
number.
2nd Phone number
*12* - - - - - - - - - #
3rd Phone number
*13* - - - - - - - - - #
4th Phone number
*14* - - - - - - - - - #
Call type
Code Data
Comments
Call type 1st number
*21* - #
0 = P100
1 = VOICE (default)
2 = Q23
3 = CPC
Call type 2nd number
*22* - #
Call type 3rd number
*23* - #
Call type 4th number
*24* - #
Call type LMS number
*30* - #
0 = P100
3 = CPC (Only battery alarm)
Test alarm/battery alarm
Code Data
Comments
LMS phone number
*16* - - - - - - - - - #
LMS (Lift Monitoring System) phone number
to alarm receiver or SLCC.
Test alarm
*17* - - - - - - - - - #
Phone number to test alarm receiver or
SLCC.
Days between tests
*27* - - #
Number of days between test alarms, 00-99
days.
Always two digits.
Test alarm protocol
*31* - #
0 = P100
3 = CPC
4 = Caller ID