16
© 2010 SafeLine and all the SafeLine products and accessories are copyrighted by law.
Programming
ENGLISH V. 4.02
OTHER CODES
CODE
DATA
COMMENTS
Detect dial tone
*83*
- #
0 = Off
1 = On (Default)
Set to off if SafeLine has problem to detect the dial tone.
Receipt to alarm receiver
*84*
- #
Select which message(s) to send to the alarm receiver at an alarm call.
0 = None (Default)
1 = Start of alarm
2 = Start+end of alarm
Break on new alarm
*86*
- #
Disconnects a call longer than 60 seconds at new activation of the alarm
button and calls the next emergency call number.
0 = OFF
1 = ON (Default)
Alarm button delay time
*87*
- - #
Delay time from pressing the alarm button until activating the alarm.
00-25 seconds. (Default = 05)
Alarm button type
*89*
- #
0 = Normally-open contact, NO (Default)
1 = Normally-closed contact, NC
Change password
*91*
- - - - #
Change password (default=0000)
Simulate an alarm event
*94*
- #
Triggers an alarm event after programming is terminated.
1 = Emergency call
2 = Test alarm
3 = Battery failure
4 = Microphone/Loudspeaker failure
5 = Emergency call
6 = Maintenance
7 = Main unit power failure
Reset to default settings
*99*
- #
1 = Factory default
2 = Default P100(The following codes will be set):
*21*0#, *22*0#, * 27*03#, *80*1#, *84*1#, *88*1#
3 = Default CPC(The following codes will be set):
*21*3#, *22*3#, *27*03#, *80*1#, *84*1#, *88*1#
4 = Default VOICE(The following codes will be set):
*21*1#, *22*1#, * 27*03#, *80*1#, *84*1#, *88*1#